2003•Clinical ChemistryOpen access

False-Positive Acetaminophen Results in a Hyperbilirubinemic Patient

Roger L Bertholf, Laura M Johannsen, Alireza Bazooband, Vafa Mansouri

Open full text 44 citations

Abstract

BACKGROUND: Acetaminophen was falsely detected in the plasma of a severely jaundiced patient, and a methodologic interference from bilirubin was suspected. METHODS: Acetaminophen was measured by an enzymatic method (GDS Diagnostics). The putative bilirubin interference was investigated in 12 hyperbilirubinemic specimens and in bilirubin linearity calibrators. The analytical method was modified to correct for background absorbance at a second wavelength. Hyperbilirubinemic specimens were fortified with acetaminophen to assess the effect of the interference on acetaminophen measurements. RESULTS: Acetaminophen was detected in 12 specimens from hyperbilirubinemic patients without a history of recent acetaminophen exposure. Dilution of hyperbilirubinemic specimens produced a nonproportional decrease in apparent acetaminophen concentrations, and no acetaminophen was detected when bilirubin was <50 mg/L. Background correction at a second wavelength failed to compensate for the interference. Although erroneous acetaminophen concentrations were detected in all specimens with high bilirubin, acetaminophen measurements in fortified specimens were accurate. CONCLUSION: The data are consistent with bilirubin interference in the enzymatic and/or chromogenic reactions involved in the acetaminophen method.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Acetaminophen was falsely detected in the plasma of a severely jaundiced patient, and a methodologic interference from bilirubin was suspected. METHODS: Acetaminophen was measured by an enzymatic method (GDS Diagnostics). The putative bilirubin interference was investigated in 12 hyperbilirubinemic specimens and in bilirubin linearity calibrators. The analytical method was modified to correct for background absorbance at a second wavelength. Hyperbilirubinemic specimens were fortified with acetaminophen to assess the effect of the interference on acetaminophen measurements. RESULTS: Acetaminophen was detected in 12 specimens from hyperbilirubinemic patients without a history of recent acetaminophen exposure. Dilution of hyperbilirubinemic specimens produced a nonproportional decrease in apparent acetaminophen concentrations, and no acetaminophen was detected when bilirubin was <50 mg/L. Background correction at a second wavelength failed to compensate for the interference. Although erroneous acetaminophen concentrations were detected in all specimens with high bilirubin, acetaminophen measurements in fortified specimens were accurate. CONCLUSION: The data are consistent with bilirubin interference in the enzymatic and/or chromogenic reactions involved in the acetaminophen method.

Why it matters

OpenAlex reports 44 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Acetaminophen was falsely detected in the plasma of a severely jaundiced patient, and a methodologic interference from bilirubin was suspected. METHODS: Acetaminophen was measured by an enzymatic method (GDS Diagnostics). The putative bilirubin interference was investigated in 12 hyperbilirubinemic specimens and in bilirubin linearity calibrators. The analytical method was modified to correct for background absorbance at a second wavelength. Hyperbilirubinemic specimens were fortified with acetaminophen to assess the effect of the interference on acetaminophen measurements. RESULTS: Acetaminophen was detected in 12 specimens from hyperbilirubinemic patients without a history of recent acetaminophen exposure. Dilution of hyperbilirubinemic specimens produced a nonproportional decrease in apparent acetaminophen concentrations, and no acetaminophen was detected when bilirubin was <50 mg/L. Background correction at a second wavelength failed to compensate for the interference. Although erroneous acetaminophen concentrations were detected in all specimens with high bilirubin, acetaminophen measurements in fortified specimens were accurate. CONCLUSION: The data are consistent with bilirubin interference in the enzymatic and/or chromogenic reactions involved in the acetaminophen method.

Key concepts: Acetaminophen, Bilirubin, Medicine, Direct bilirubin, Absorbance, Antipyretic, Internal medicine, Chemistry