2014•Applied Mechanics and MaterialsOpen access

Evaluation of Indoor Thermal Environment in a Radiant-Cooled-Floor Office Building in Malaysia

Qi Jie Kwong, Mohamad Afri Arsad, Nor Mariah Adam

Open full text 4 citations

Abstract

This paper presents the findings of a thermal comfort survey conducted in a tropical green office building. The building was installed with a slab-integrated radiant cooling system, which operated concurrently with an integrated variable-air-volume system. Evaluation of indoor thermal environment was made, where both objective and subjective assessments were carried out. The air temperature, air velocity, relative humidity and surface temperatures were measured by using calibrated sensors. Based on the data collected from the field assessment, the thermal comforts indices with expectancy factor were calculated. The results showed that thermal comfort parameters were within the comfort range specified in a local guideline, except for the air velocity profile. Besides, discrepancy between the Predicted Mean Vote (PMV) with expectancy factor and Actual Mean Vote (AMV) was found, which showed that the former still overestimated the thermal sensation of occupants although an expectancy factor of 0.5 was used.

About this research paper

What this paper is about

This paper presents the findings of a thermal comfort survey conducted in a tropical green office building. The building was installed with a slab-integrated radiant cooling system, which operated concurrently with an integrated variable-air-volume system. Evaluation of indoor thermal environment was made, where both objective and subjective assessments were carried out. The air temperature, air velocity, relative humidity and surface temperatures were measured by using calibrated sensors. Based on the data collected from the field assessment, the thermal comforts indices with expectancy factor were calculated. The results showed that thermal comfort parameters were within the comfort range specified in a local guideline, except for the air velocity profile. Besides, discrepancy between the Predicted Mean Vote (PMV) with expectancy factor and Actual Mean Vote (AMV) was found, which showed that the former still overestimated the thermal sensation of occupants although an expectancy factor of 0.5 was used.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper presents the findings of a thermal comfort survey conducted in a tropical green office building. The building was installed with a slab-integrated radiant cooling system, which operated concurrently with an integrated variable-air-volume system. Evaluation of indoor thermal environment was made, where both objective and subjective assessments were carried out. The air temperature, air velocity, relative humidity and surface temperatures were measured by using calibrated sensors. Based on the data collected from the field assessment, the thermal comforts indices with expectancy factor were calculated. The results showed that thermal comfort parameters were within the comfort range specified in a local guideline, except for the air velocity profile. Besides, discrepancy between the Predicted Mean Vote (PMV) with expectancy factor and Actual Mean Vote (AMV) was found, which showed that the former still overestimated the thermal sensation of occupants although an expectancy factor of 0.5 was used.

Key concepts: Thermal comfort, Relative humidity, Air velocity, Radiant cooling, Environmental science, Thermal sensation, Mean radiant temperature, Indoor air

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of Indoor Thermal Environment in a Radiant-Cooled-Floor Office Building in Malaysia — Research Paper | ScholarLens