2014Applied Mechanics and MaterialsRequires access

Analysis on Thermal Comfort of Air-Conditioned Buildings in Malaysia: Case Study of Universiti Tenaga Nasional

Iman Asadi, Ibrahim Hussein, Kumaran Palanisamy

Open publisher page 5 citations

Abstract

Field study was carried out on the thermal conditions and thermal comfort of occupants in air conditioned buildings in Malaysia. The study was carried out in 10 staff offices and 6 student study areas of Universiti Tenaga Nasional (UNITEN) during October and November 2013, collecting a full set of objective physical measurements and subjective assessments through questionnaires. The measured environmental parameters were air temperature, relative humidity and air velocity. The subjective responses concern the judgment of the occupants about the thermal environment at the moment of measurements. The obtained results showed that most places are in acceptable and comfort zone according to Fanger’s predicted mean vote (PMV) model. The neutral air temperature obtained through linear regression analysis of thermal sensation vote (TSV) is 23.9°C for UNITEN. The result of this study demonstrates that the acceptability of thermal comfort among UNITEN occupant is about 78 %.

About this research paper

What this paper is about

Field study was carried out on the thermal conditions and thermal comfort of occupants in air conditioned buildings in Malaysia. The study was carried out in 10 staff offices and 6 student study areas of Universiti Tenaga Nasional (UNITEN) during October and November 2013, collecting a full set of objective physical measurements and subjective assessments through questionnaires. The measured environmental parameters were air temperature, relative humidity and air velocity. The subjective responses concern the judgment of the occupants about the thermal environment at the moment of measurements. The obtained results showed that most places are in acceptable and comfort zone according to Fanger’s predicted mean vote (PMV) model. The neutral air temperature obtained through linear regression analysis of thermal sensation vote (TSV) is 23.9°C for UNITEN. The result of this study demonstrates that the acceptability of thermal comfort among UNITEN occupant is about 78 %.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Field study was carried out on the thermal conditions and thermal comfort of occupants in air conditioned buildings in Malaysia. The study was carried out in 10 staff offices and 6 student study areas of Universiti Tenaga Nasional (UNITEN) during October and November 2013, collecting a full set of objective physical measurements and subjective assessments through questionnaires. The measured environmental parameters were air temperature, relative humidity and air velocity. The subjective responses concern the judgment of the occupants about the thermal environment at the moment of measurements. The obtained results showed that most places are in acceptable and comfort zone according to Fanger’s predicted mean vote (PMV) model. The neutral air temperature obtained through linear regression analysis of thermal sensation vote (TSV) is 23.9°C for UNITEN. The result of this study demonstrates that the acceptability of thermal comfort among UNITEN occupant is about 78 %.

Key concepts: Thermal comfort, Thermal sensation, Air velocity, Relative humidity, Air temperature, Operative temperature, Architectural engineering, Environmental science

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis on Thermal Comfort of Air-Conditioned Buildings in Malaysia: Case Study of Universiti Tenaga Nasional — Research Paper | ScholarLens