2013Journal of the American Animal Hospital AssociationRequires access

Evaluation of a Gelatin Matrix as a Topical Hemostatic Agent for Hepatic Bleeding in the Dog

Daniel P. Polidoro, Philip H. Kass

Open publisher page 10 citations

Abstract

New generation topical hemostatic agents containing thrombin have been developed for use in surgical procedures when control of bleeding by conventional methods is either ineffective or impractical. The authors compared the safety, hemostatic efficacy, and handling characteristics of a thrombin-containing topical surgical hemostatic agent (a gelatin matrix) to a hemostatic gelatin sponge for treatment of parenchymal bleeding after liver biopsy. Fourteen dogs were enrolled in this prospective clinical study. Paired 1.5 cm × 1.5 cm and 0.5 cm deep liver biopsies were obtained via laparotomy for each dog. One bleeding liver biopsy lesion was treated with the gelatin matrix and the other with a gelatin sponge. The treated liver biopsy sites were compared for bleeding severity, time to hemostasis, cumulative blood loss, and hemostatic agent handling characteristics. Median time to hemostasis was significantly shorter (P = 0.034) and median cumulative blood loss was significantly lower (P = 0.033) for the lesions treated with the gelatin matrix than the gelatin sponge. Adverse reactions were not observed within the first 24 hr postoperatively. When used to control parenchymal bleeding from liver biopsy sites in the dog, the evaluated gelatin matrix was safe and more effective than the gelatin sponge.

About this research paper

What this paper is about

New generation topical hemostatic agents containing thrombin have been developed for use in surgical procedures when control of bleeding by conventional methods is either ineffective or impractical. The authors compared the safety, hemostatic efficacy, and handling characteristics of a thrombin-containing topical surgical hemostatic agent (a gelatin matrix) to a hemostatic gelatin sponge for treatment of parenchymal bleeding after liver biopsy. Fourteen dogs were enrolled in this prospective clinical study. Paired 1.5 cm × 1.5 cm and 0.5 cm deep liver biopsies were obtained via laparotomy for each dog. One bleeding liver biopsy lesion was treated with the gelatin matrix and the other with a gelatin sponge. The treated liver biopsy sites were compared for bleeding severity, time to hemostasis, cumulative blood loss, and hemostatic agent handling characteristics. Median time to hemostasis was significantly shorter (P = 0.034) and median cumulative blood loss was significantly lower (P = 0.033) for the lesions treated with the gelatin matrix than the gelatin sponge. Adverse reactions were not observed within the first 24 hr postoperatively. When used to control parenchymal bleeding from liver biopsy sites in the dog, the evaluated gelatin matrix was safe and more effective than the gelatin sponge.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

New generation topical hemostatic agents containing thrombin have been developed for use in surgical procedures when control of bleeding by conventional methods is either ineffective or impractical. The authors compared the safety, hemostatic efficacy, and handling characteristics of a thrombin-containing topical surgical hemostatic agent (a gelatin matrix) to a hemostatic gelatin sponge for treatment of parenchymal bleeding after liver biopsy. Fourteen dogs were enrolled in this prospective clinical study. Paired 1.5 cm × 1.5 cm and 0.5 cm deep liver biopsies were obtained via laparotomy for each dog. One bleeding liver biopsy lesion was treated with the gelatin matrix and the other with a gelatin sponge. The treated liver biopsy sites were compared for bleeding severity, time to hemostasis, cumulative blood loss, and hemostatic agent handling characteristics. Median time to hemostasis was significantly shorter (P = 0.034) and median cumulative blood loss was significantly lower (P = 0.033) for the lesions treated with the gelatin matrix than the gelatin sponge. Adverse reactions were not observed within the first 24 hr postoperatively. When used to control parenchymal bleeding from liver biopsy sites in the dog, the evaluated gelatin matrix was safe and more effective than the gelatin sponge.

Key concepts: Medicine, Gelatin, Hemostasis, Hemostatic Agent, Hemostatics, Gelatin sponge, Biopsy, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of a Gelatin Matrix as a Topical Hemostatic Agent for Hepatic Bleeding in the Dog — Research Paper | ScholarLens