Straight Benthic Flow-Through Flume for In Situ Measurement of Cohesive Sediment Dynamics
Jochen Aberle, Vladimir Nikora, S. R. McLean, Crile Doscher, Ian McEwan, M. Green, Derek G. Goring, Jeremy Walsh
Abstract
Jochen Aberle, Vladimir Nikora, S. R. McLean, Crile Doscher, Ian McEwan, M. Green, Derek G. Goring, Jeremy Walsh
Abstract
The design of a straight benthic flow-through flume for in situ studies of cohesive sediment dynamics is described including the flume structure and probes installed for routine measurements of suspended sediments and flow velocity. The flume was calibrated for two roughness types covering the range of possible cohesive bed roughnesses. The calibration included a set of three-dimensional velocity measurements using acoustic Doppler velocimeter. These measurements were used to develop calibration relationships between the bed shear stress (which is difficult to measure directly in routine deployments) and the flume centerline flow velocity, which is routinely measured. An example of a successful deployment of the flume is presented. The limitations and potential for further improvements are also briefly discussed.
OpenAlex reports 43 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The design of a straight benthic flow-through flume for in situ studies of cohesive sediment dynamics is described including the flume structure and probes installed for routine measurements of suspended sediments and flow velocity. The flume was calibrated for two roughness types covering the range of possible cohesive bed roughnesses. The calibration included a set of three-dimensional velocity measurements using acoustic Doppler velocimeter. These measurements were used to develop calibration relationships between the bed shear stress (which is difficult to measure directly in routine deployments) and the flume centerline flow velocity, which is routinely measured. An example of a successful deployment of the flume is presented. The limitations and potential for further improvements are also briefly discussed.
Key concepts: Flume, Acoustic Doppler velocimetry, Geotechnical engineering, Geology, Wave flume, Calibration, Benthic zone, Flow (mathematics)