Nitrous Oxide Induces Paradoxical Electroencephalographic Changes After Tracheal Intubation During Isoflurane and Sevoflurane Anesthesia
Yutaka Oda, Katsuaki Tanaka, Tadashi Matsuura, Ichiro Hase, Kiyonobu Nishikawa, Akira Asada
Abstract
Yutaka Oda, Katsuaki Tanaka, Tadashi Matsuura, Ichiro Hase, Kiyonobu Nishikawa, Akira Asada
Abstract
In Brief In this randomized, double-blind, controlled study, we tested the hypothesis that nitrous oxide (N2O) affects bispectral index (BIS) and 95% spectral edge frequency (SEF95) in response to tracheal intubation during anesthesia with isoflurane and sevoflurane. In protocol 1, we randomly allocated 90 ASA physical status I patients to 6 groups (n = 15 each). Anesthesia was induced with isoflurane or sevoflurane with 0%, 33%, or 66% N2O. The concentration of isoflurane and sevoflurane was gradually increased and end-tidal concentrations were maintained at 1.1% and 1.7%, respectively. Tracheal intubation was performed 12 min after induction of anesthesia. BIS was significantly increased 1 min after tracheal intubation compared before laryngoscopy in patients receiving only isoflurane or sevoflurane (P = 0.001 and 0.007, respectively). In patients receiving 66% N2O-isoflurane or 66% N2O-sevoflurane, both BIS and SEF95 were significantly decreased after tracheal intubation and significantly lower than in those patients receiving only isoflurane or sevoflurane, respectively (P < 0.01 for both). In protocol 2, 3 μg/kg of IV fentanyl completely abolished the decrease of BIS and SEF95 after tracheal intubation during anesthesia with 66% N2O-isoflurane and 66% N2O-sevoflurane (n = 10). We conclude that 66% N2O induced a paradoxical decrease of BIS in response to tracheal intubation during anesthesia with isoflurane and sevoflurane. IMPLICATIONS: During isoflurane and sevoflurane anesthesia, addition of nitrous oxide decreased the frequency of electroencephalogram and bispectral index (BIS) but did not suppress hemodynamic changes in response to tracheal intubation. These electroencephalographic changes with a decrease of BIS are caused by paradoxical arousal.
OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In Brief In this randomized, double-blind, controlled study, we tested the hypothesis that nitrous oxide (N2O) affects bispectral index (BIS) and 95% spectral edge frequency (SEF95) in response to tracheal intubation during anesthesia with isoflurane and sevoflurane. In protocol 1, we randomly allocated 90 ASA physical status I patients to 6 groups (n = 15 each). Anesthesia was induced with isoflurane or sevoflurane with 0%, 33%, or 66% N2O. The concentration of isoflurane and sevoflurane was gradually increased and end-tidal concentrations were maintained at 1.1% and 1.7%, respectively. Tracheal intubation was performed 12 min after induction of anesthesia. BIS was significantly increased 1 min after tracheal intubation compared before laryngoscopy in patients receiving only isoflurane or sevoflurane (P = 0.001 and 0.007, respectively). In patients receiving 66% N2O-isoflurane or 66% N2O-sevoflurane, both BIS and SEF95 were significantly decreased after tracheal intubation and significantly lower than in those patients receiving only isoflurane or sevoflurane, respectively (P < 0.01 for both). In protocol 2, 3 μg/kg of IV fentanyl completely abolished the decrease of BIS and SEF95 after tracheal intubation during anesthesia with 66% N2O-isoflurane and 66% N2O-sevoflurane (n = 10). We conclude that 66% N2O induced a paradoxical decrease of BIS in response to tracheal intubation during anesthesia with isoflurane and sevoflurane. IMPLICATIONS: During isoflurane and sevoflurane anesthesia, addition of nitrous oxide decreased the frequency of electroencephalogram and bispectral index (BIS) but did not suppress hemodynamic changes in response to tracheal intubation. These electroencephalographic changes with a decrease of BIS are caused by paradoxical arousal.
Key concepts: Isoflurane, Sevoflurane, Bispectral index, Anesthesia, Tracheal intubation, Medicine, Intubation, Nitrous oxide