1990•Acta OphthalmologicaRequires access

The effect of reduced tear drainage on corneal and aqueous concentrations of topically applied fluorescein

Christina Lindén, Albert Alm

Open publisher page 14 citations

Abstract

The effect of reduced tear drainage on the intraocular penetration of topically applied fluorescein was studied with fluorophotometry in healthy eyes. Corneal and aqueous fluorescein concentrations could not be followed for the first hour after application of fluorescein because tear film fluorescense influenced fluorophotometric determinations of fluorescein concentrations in cornea and aqueous for at least 30 min. Insertion of punctal plugs in the upper and lower punctum of one eye caused a significant (P less than 0.025) increase in aqueous fluorescein concentrations 1 to 8 h after application of 20 microliters of a 2% solution of sodium fluorescein in the lower conjunctival sac. The achieved concentrations were almost 4 times as large as in the fellow eye. There was some individual variation, but a marked increase was observed in 9 of 11 subjects. Attempts to reduce tear drainage by compressing the tear sac and/or closing the eye lids for 1 min after application of the eye drop had no significant effect on corneal or aqueous concentrations of fluorescein 1 to 8 h later.

About this research paper

What this paper is about

The effect of reduced tear drainage on the intraocular penetration of topically applied fluorescein was studied with fluorophotometry in healthy eyes. Corneal and aqueous fluorescein concentrations could not be followed for the first hour after application of fluorescein because tear film fluorescense influenced fluorophotometric determinations of fluorescein concentrations in cornea and aqueous for at least 30 min. Insertion of punctal plugs in the upper and lower punctum of one eye caused a significant (P less than 0.025) increase in aqueous fluorescein concentrations 1 to 8 h after application of 20 microliters of a 2% solution of sodium fluorescein in the lower conjunctival sac. The achieved concentrations were almost 4 times as large as in the fellow eye. There was some individual variation, but a marked increase was observed in 9 of 11 subjects. Attempts to reduce tear drainage by compressing the tear sac and/or closing the eye lids for 1 min after application of the eye drop had no significant effect on corneal or aqueous concentrations of fluorescein 1 to 8 h later.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The effect of reduced tear drainage on the intraocular penetration of topically applied fluorescein was studied with fluorophotometry in healthy eyes. Corneal and aqueous fluorescein concentrations could not be followed for the first hour after application of fluorescein because tear film fluorescense influenced fluorophotometric determinations of fluorescein concentrations in cornea and aqueous for at least 30 min. Insertion of punctal plugs in the upper and lower punctum of one eye caused a significant (P less than 0.025) increase in aqueous fluorescein concentrations 1 to 8 h after application of 20 microliters of a 2% solution of sodium fluorescein in the lower conjunctival sac. The achieved concentrations were almost 4 times as large as in the fellow eye. There was some individual variation, but a marked increase was observed in 9 of 11 subjects. Attempts to reduce tear drainage by compressing the tear sac and/or closing the eye lids for 1 min after application of the eye drop had no significant effect on corneal or aqueous concentrations of fluorescein 1 to 8 h later.

Key concepts: Fluorescein, Ophthalmology, Cornea, Sodium fluorescein, Aqueous humour, Aqueous humor, Slit lamp, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
The effect of reduced tear drainage on corneal and aqueous concentrations of topically applied fluorescein — Research Paper | ScholarLens