1990PubMedRequires access

Effect of fluorescein on the electrical potential difference across isolated rabbit corneal endothelium.

Ritsuko Akiyama, J.P. Koniarek, Jorge Fischbarg

Open publisher page 4 citations

Abstract

The authors investigated whether fluorescein sodium affects the in vitro endothelial function of rabbit corneas. As an index of this function, the transendothelial electrical potential difference (TEPD) was used. The TEPD in a balanced salts and glucose (BSG) control solution increased for the first 30 min and then decayed slowly, reaching about 60% of its original value after 5 hr. When a BSG solution containing 5 micrograms/ml of fluorescein sodium was used, the TEPD time course was similar to the control solution. Since this fluorescein sodium concentration is about sevenfold higher than that seen in the anterior chamber of ocular patients, these results reassure users that no toxic effect of fluorescein is discernible at concentrations relevant to ophthalmic practice. With a fluorescein sodium concentration of 500 micrograms/ml, the TEPD decreased below control values after 4 hr of exposure, but such a concentration is approximately 5000-fold higher than that seen in the anterior chamber of patients. The adverse effect of fluorescein on TEPD is probably irrelevant for standard systemic clinical use.

About this research paper

What this paper is about

The authors investigated whether fluorescein sodium affects the in vitro endothelial function of rabbit corneas. As an index of this function, the transendothelial electrical potential difference (TEPD) was used. The TEPD in a balanced salts and glucose (BSG) control solution increased for the first 30 min and then decayed slowly, reaching about 60% of its original value after 5 hr. When a BSG solution containing 5 micrograms/ml of fluorescein sodium was used, the TEPD time course was similar to the control solution. Since this fluorescein sodium concentration is about sevenfold higher than that seen in the anterior chamber of ocular patients, these results reassure users that no toxic effect of fluorescein is discernible at concentrations relevant to ophthalmic practice. With a fluorescein sodium concentration of 500 micrograms/ml, the TEPD decreased below control values after 4 hr of exposure, but such a concentration is approximately 5000-fold higher than that seen in the anterior chamber of patients. The adverse effect of fluorescein on TEPD is probably irrelevant for standard systemic clinical use.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The authors investigated whether fluorescein sodium affects the in vitro endothelial function of rabbit corneas. As an index of this function, the transendothelial electrical potential difference (TEPD) was used. The TEPD in a balanced salts and glucose (BSG) control solution increased for the first 30 min and then decayed slowly, reaching about 60% of its original value after 5 hr. When a BSG solution containing 5 micrograms/ml of fluorescein sodium was used, the TEPD time course was similar to the control solution. Since this fluorescein sodium concentration is about sevenfold higher than that seen in the anterior chamber of ocular patients, these results reassure users that no toxic effect of fluorescein is discernible at concentrations relevant to ophthalmic practice. With a fluorescein sodium concentration of 500 micrograms/ml, the TEPD decreased below control values after 4 hr of exposure, but such a concentration is approximately 5000-fold higher than that seen in the anterior chamber of patients. The adverse effect of fluorescein on TEPD is probably irrelevant for standard systemic clinical use.

Key concepts: Fluorescein, Sodium fluorescein, Sodium, Corneal endothelium, Chemistry, Ophthalmology, Chromatography, Cornea

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of fluorescein on the electrical potential difference across isolated rabbit corneal endothelium. — Research Paper | ScholarLens