Effects of Abnormal Hemoglobin Concentration in Human Blood on Membrane Diffusing Capacity of the Lung and on Pulmonary Capillary Blood Volume
G. Riepl
Abstract
G. Riepl
Abstract
In 13 patients with chronic anemia or polycythemia but normal lung function, and in 7 healthy students a statistically significant correlation between hemoglobin concentration and membrane diffusing capacity of the lung for CO was found. A membrane diffusing constant resulting from extrapolation for hemoglobin concentration 0 g/ was 13.4% of the predicted value (100% for Hb = 14.5 g%). A change of 1 g hemoglobin/100 ml changes membrane diffusing capacity for 6.3% of the predicted value. This result confirms the theory of Koyama and Mochizuki that the diffusing capacity of the pulmonary membrane is a function of the hemoglobin concentration of pulmonary capillary blood. In 3 healthy subjects with normal hemoglobin concentration the effect of DL/VA inhomogenities in the lung on single-breath diffusing capacity and its subdivisions was examined. An increase of DLCO for 20% of predicted normal at decreasing apnea time (tA = 5 sec) resulted from an increased pulmonary capillary blood volume for 50--90% of the predicted value (at tA = 10 sec), whereas membrane diffusing capacity remained unchanged over the range of apnea times. The reasons for this finding are still unknown; alteration of pulmonary perfusion at changing apnea time is taken into account.
OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
In 13 patients with chronic anemia or polycythemia but normal lung function, and in 7 healthy students a statistically significant correlation between hemoglobin concentration and membrane diffusing capacity of the lung for CO was found. A membrane diffusing constant resulting from extrapolation for hemoglobin concentration 0 g/ was 13.4% of the predicted value (100% for Hb = 14.5 g%). A change of 1 g hemoglobin/100 ml changes membrane diffusing capacity for 6.3% of the predicted value. This result confirms the theory of Koyama and Mochizuki that the diffusing capacity of the pulmonary membrane is a function of the hemoglobin concentration of pulmonary capillary blood. In 3 healthy subjects with normal hemoglobin concentration the effect of DL/VA inhomogenities in the lung on single-breath diffusing capacity and its subdivisions was examined. An increase of DLCO for 20% of predicted normal at decreasing apnea time (tA = 5 sec) resulted from an increased pulmonary capillary blood volume for 50--90% of the predicted value (at tA = 10 sec), whereas membrane diffusing capacity remained unchanged over the range of apnea times. The reasons for this finding are still unknown; alteration of pulmonary perfusion at changing apnea time is taken into account.
Key concepts: Diffusing capacity, Pulmonary Diffusing Capacity, DLCO, Hemoglobin, Pulmonary function testing, Medicine, Lung volumes, Lung