1972IEEE Transactions on Nuclear ScienceOpen access

High-Purity Germanium: Detector Fabrication and Performance

Richard H. Pehl, Richard C. Cordi, Fred S. Goulding

Open full text 48 citations

Abstract

The availability of germanium with less than 1010 acceptors/cm3 has enabled us to fabricate and study the performance of germanium detectors of substantially larger volume than has hitherto been possible except by using lithium-drifting techniques. Detectors having a sensitive volume of up to 25 cm3 have been made. These detectors have a lithium diffused n+ contact and a metal barrier non-injecting back contact, and are totally depleted. The energy resolution of these detectors is similar to that of equivalent sized lithium-drifted detectors, but the high-purity detectors are easier to fabricate, and present considerably fewer handling problems.

Open-access reader

About this research paper

What this paper is about

The availability of germanium with less than 1010 acceptors/cm3 has enabled us to fabricate and study the performance of germanium detectors of substantially larger volume than has hitherto been possible except by using lithium-drifting techniques. Detectors having a sensitive volume of up to 25 cm3 have been made. These detectors have a lithium diffused n+ contact and a metal barrier non-injecting back contact, and are totally depleted. The energy resolution of these detectors is similar to that of equivalent sized lithium-drifted detectors, but the high-purity detectors are easier to fabricate, and present considerably fewer handling problems.

Why it matters

OpenAlex reports 48 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The availability of germanium with less than 1010 acceptors/cm3 has enabled us to fabricate and study the performance of germanium detectors of substantially larger volume than has hitherto been possible except by using lithium-drifting techniques. Detectors having a sensitive volume of up to 25 cm3 have been made. These detectors have a lithium diffused n+ contact and a metal barrier non-injecting back contact, and are totally depleted. The energy resolution of these detectors is similar to that of equivalent sized lithium-drifted detectors, but the high-purity detectors are easier to fabricate, and present considerably fewer handling problems.

Key concepts: Germanium, Detector, Semiconductor detector, Fabrication, Materials science, Lithium (medication), Optoelectronics, Particle detector

Related papers