2000Review of Scientific InstrumentsRequires access

Performance of a very high resolution soft x-ray beamline BL25SU with a twin-helical undulator at SPring-8

Y. Saitoh, Hiroaki Kimura, Yoshio Suzuki, Takeshi Nakatani, T. Matsushita, Takayuki Muro, Tsuneaki Miyahara, M. Fujisawa, Kazuo Soda, Shigenori Ueda, H. Harada, Masato Kotsugi, A. Sekiyama, S. Suga

Open publisher page 194 citations

Abstract

We report on the excellent performance of a newly constructed soft x-ray helical undulator beamline BL25SU of SPring-8 for photon energies 500–1800 eV. The full beamline was designed to perform very high resolution soft x-ray spectroscopy of solids with using high brilliance, highly circularly polarized undulator radiation. The grazing incidence monochromator employs varied-line-spacing plane gratings which operate in convergent light from a spherical mirror and focuses monochromatic light onto the exit slit. A resolving power in excess of 15 000 was measured at 540 and 870 eV for a grating with a central groove density of 600 lines/mm from the photoemission spectra of Au. A resolving power of more than 20 000 is estimated near 870 eV for a grating with a central groove density of 1000 lines/mm. A photon flux of more than 1×1011 photons/s/100 mA/0.02% b.w. is supplied onto the sample between 500 and 1800 eV with very low amount of higher-order light. The low heat load from the twin-helical undulator gives high stability to all optical components, which is essential to obtain high resolution in a wide energy region. Three experimental stations are installed in tandem on this beamline for various high resolution spectroscopy measurements.

About this research paper

What this paper is about

We report on the excellent performance of a newly constructed soft x-ray helical undulator beamline BL25SU of SPring-8 for photon energies 500–1800 eV. The full beamline was designed to perform very high resolution soft x-ray spectroscopy of solids with using high brilliance, highly circularly polarized undulator radiation. The grazing incidence monochromator employs varied-line-spacing plane gratings which operate in convergent light from a spherical mirror and focuses monochromatic light onto the exit slit. A resolving power in excess of 15 000 was measured at 540 and 870 eV for a grating with a central groove density of 600 lines/mm from the photoemission spectra of Au. A resolving power of more than 20 000 is estimated near 870 eV for a grating with a central groove density of 1000 lines/mm. A photon flux of more than 1×1011 photons/s/100 mA/0.02% b.w. is supplied onto the sample between 500 and 1800 eV with very low amount of higher-order light. The low heat load from the twin-helical undulator gives high stability to all optical components, which is essential to obtain high resolution in a wide energy region. Three experimental stations are installed in tandem on this beamline for various high resolution spectroscopy measurements.

Why it matters

OpenAlex reports 194 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We report on the excellent performance of a newly constructed soft x-ray helical undulator beamline BL25SU of SPring-8 for photon energies 500–1800 eV. The full beamline was designed to perform very high resolution soft x-ray spectroscopy of solids with using high brilliance, highly circularly polarized undulator radiation. The grazing incidence monochromator employs varied-line-spacing plane gratings which operate in convergent light from a spherical mirror and focuses monochromatic light onto the exit slit. A resolving power in excess of 15 000 was measured at 540 and 870 eV for a grating with a central groove density of 600 lines/mm from the photoemission spectra of Au. A resolving power of more than 20 000 is estimated near 870 eV for a grating with a central groove density of 1000 lines/mm. A photon flux of more than 1×1011 photons/s/100 mA/0.02% b.w. is supplied onto the sample between 500 and 1800 eV with very low amount of higher-order light. The low heat load from the twin-helical undulator gives high stability to all optical components, which is essential to obtain high resolution in a wide energy region. Three experimental stations are installed in tandem on this beamline for various high resolution spectroscopy measurements.

Key concepts: Beamline, Undulator, Monochromator, SPring-8, Optics, Physics, Synchrotron radiation, Grating

Related papers

Back to paper searchBrowse research topicsOriginal source
Performance of a very high resolution soft x-ray beamline BL25SU with a twin-helical undulator at SPring-8 — Research Paper | ScholarLens