1997Pacing and Clinical ElectrophysiologyRequires access

Use of an Orthogonal Electrode Array to Identify the Successful Ablation Site in Right Ventricular Outflow Tract Tachycardia

Westby G. Fisher, Martin E. Bacon, John Swartz

Open publisher page 5 citations

Abstract

A novel approach to localize the origin of a right ventricular outflow tract tachycardia using an ablation catheter having an orthogonally oriented electrode array is described. Bipolar electrogram polarity reversal using minimally filtered (1-500 Hz) electrograms simultaneously acquired in two axes from the ablation catheter permitted accurate localization of the tachycardia focus. A single radiofrequency energy application at the site identified by this technique resulted in successful tachycardia ablation. This technique may facilitate mapping of any arrhythmia which can be modeled as arising from a point source.

About this research paper

What this paper is about

A novel approach to localize the origin of a right ventricular outflow tract tachycardia using an ablation catheter having an orthogonally oriented electrode array is described. Bipolar electrogram polarity reversal using minimally filtered (1-500 Hz) electrograms simultaneously acquired in two axes from the ablation catheter permitted accurate localization of the tachycardia focus. A single radiofrequency energy application at the site identified by this technique resulted in successful tachycardia ablation. This technique may facilitate mapping of any arrhythmia which can be modeled as arising from a point source.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel approach to localize the origin of a right ventricular outflow tract tachycardia using an ablation catheter having an orthogonally oriented electrode array is described. Bipolar electrogram polarity reversal using minimally filtered (1-500 Hz) electrograms simultaneously acquired in two axes from the ablation catheter permitted accurate localization of the tachycardia focus. A single radiofrequency energy application at the site identified by this technique resulted in successful tachycardia ablation. This technique may facilitate mapping of any arrhythmia which can be modeled as arising from a point source.

Key concepts: Medicine, Ablation, Ventricular outflow tract, Cardiology, Outflow, Internal medicine, Ventricular tachycardia, Tachycardia

Related papers

Back to paper searchBrowse research topicsOriginal source
Use of an Orthogonal Electrode Array to Identify the Successful Ablation Site in Right Ventricular Outflow Tract Tachycardia — Research Paper | ScholarLens