The Outlined Structure of The Recommendation on Performance-Based Fire Safety Design -Chapter 3 Fire Safety of Individual Buildings-
Takeyoshi Tanaka, Mitsuo Kadoya
Abstract
Open-access reader
Takeyoshi Tanaka, Mitsuo Kadoya
Abstract
Open-access reader
Significant number of occupants may have impaired ability to evacuate room of dwelling house, waiting room of hospital, nursery of day care center, child room in kindergarten, café, drinking facility V3Majority of occupants have impaired ability to evacuate patient room, living room of elderly people's home. Chapter 3 Fire Safety of Individual Buildings 29 Familiarity with spaces of buildingTables 3.3 Classification of space based on familiarity with building space Class Character of space use Example of space uses F1 Majority of occupants are familiar with space dwelling house, dormitory, office, education, company canteen, warehouse F2 Significant number of occupants may not be familiar with the space conference, hospital, library, gymnasium, sports facility, city hall F3 Majority of occupants are not familiar with the space retail, restaurant, café, drinking facility, hotel or inn, theater, movie theater, cabaret, assembly, amusement, exhibition, museum 3.1.2.4 Density of occupants Tables 3.4 Classification of spaces based on density of occupants Class character of the space example of the space use D1 Low occupant density room of house, room of dormitory, room of hotel or inn, patient room, library, sports arena D2 Moderate occupant density office, conference room, retail, museum, exposition D3 High occupant density theater auditorium, assembly, classroom, amusement, exhibition, waiting room, stand of sports facility
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Significant number of occupants may have impaired ability to evacuate room of dwelling house, waiting room of hospital, nursery of day care center, child room in kindergarten, café, drinking facility V3Majority of occupants have impaired ability to evacuate patient room, living room of elderly people's home. Chapter 3 Fire Safety of Individual Buildings 29 Familiarity with spaces of buildingTables 3.3 Classification of space based on familiarity with building space Class Character of space use Example of space uses F1 Majority of occupants are familiar with space dwelling house, dormitory, office, education, company canteen, warehouse F2 Significant number of occupants may not be familiar with the space conference, hospital, library, gymnasium, sports facility, city hall F3 Majority of occupants are not familiar with the space retail, restaurant, café, drinking facility, hotel or inn, theater, movie theater, cabaret, assembly, amusement, exhibition, museum 3.1.2.4 Density of occupants Tables 3.4 Classification of spaces based on density of occupants Class character of the space example of the space use D1 Low occupant density room of house, room of dormitory, room of hotel or inn, patient room, library, sports arena D2 Moderate occupant density office, conference room, retail, museum, exposition D3 High occupant density theater auditorium, assembly, classroom, amusement, exhibition, waiting room, stand of sports facility
Key concepts: Fire safety, Architectural engineering, Engineering, Forensic engineering, Fire protection, Fire performance, Environmental science, Construction engineering