2004Spinal SurgeryOpen access

Complications related to an Interlaminar Fixation Device supplemented to Transarticular Screw Fixation of Atlantoaxial Joint

Fumio Suzuki, Atsushi B. Tsuji, Hiroshi Katō, Masayuki Matsuda

Open full text 0 citations

Abstract

In atlantoaxial transarticular screw fixation, two screws are usually used to fix both sides of the joint, but not in all cases. We have experienced two cases in which one of the two screws was not able to be applied, because of the high-riding of a vertebral artery and a severe deformity of C2/3 facet. In order to increase the stability, we used the Trois-X system (3XS), which is a rod and clamp system having a transverse bar, for posterior interlaminar fixation. Contrary to our expectation, we had a complication with this device. In the atlantoaxial transarticular screw fixation, C1/2 joints were fixed in neutral position in contrast to the posterior interlaminar fixation that fixes C1/2 in an extended position. So less room is available between the occiput and C1 posterior arch for the screw fixation. Since some parts of 3XS extend over the C1 posterior arch, the room between the C1 and the occiput was reduced and the device came in contact with the occipital bone in extension. The contact induced osteolysis of the C1 lateral mass that required a second operation. In atlantoaxial transarticular screw fixation, this bulky device should be used carefully for interlaminar fixation, especially for the patients having a short distance between the occiput and C1 posterior arch.

Open-access reader

About this research paper

What this paper is about

In atlantoaxial transarticular screw fixation, two screws are usually used to fix both sides of the joint, but not in all cases. We have experienced two cases in which one of the two screws was not able to be applied, because of the high-riding of a vertebral artery and a severe deformity of C2/3 facet. In order to increase the stability, we used the Trois-X system (3XS), which is a rod and clamp system having a transverse bar, for posterior interlaminar fixation. Contrary to our expectation, we had a complication with this device. In the atlantoaxial transarticular screw fixation, C1/2 joints were fixed in neutral position in contrast to the posterior interlaminar fixation that fixes C1/2 in an extended position. So less room is available between the occiput and C1 posterior arch for the screw fixation. Since some parts of 3XS extend over the C1 posterior arch, the room between the C1 and the occiput was reduced and the device came in contact with the occipital bone in extension. The contact induced osteolysis of the C1 lateral mass that required a second operation. In atlantoaxial transarticular screw fixation, this bulky device should be used carefully for interlaminar fixation, especially for the patients having a short distance between the occiput and C1 posterior arch.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In atlantoaxial transarticular screw fixation, two screws are usually used to fix both sides of the joint, but not in all cases. We have experienced two cases in which one of the two screws was not able to be applied, because of the high-riding of a vertebral artery and a severe deformity of C2/3 facet. In order to increase the stability, we used the Trois-X system (3XS), which is a rod and clamp system having a transverse bar, for posterior interlaminar fixation. Contrary to our expectation, we had a complication with this device. In the atlantoaxial transarticular screw fixation, C1/2 joints were fixed in neutral position in contrast to the posterior interlaminar fixation that fixes C1/2 in an extended position. So less room is available between the occiput and C1 posterior arch for the screw fixation. Since some parts of 3XS extend over the C1 posterior arch, the room between the C1 and the occiput was reduced and the device came in contact with the occipital bone in extension. The contact induced osteolysis of the C1 lateral mass that required a second operation. In atlantoaxial transarticular screw fixation, this bulky device should be used carefully for interlaminar fixation, especially for the patients having a short distance between the occiput and C1 posterior arch.

Key concepts: Occiput, Medicine, Fixation (population genetics), Vertebral artery, Atlantoaxial instability, Occipital bone, Lateral mass, Deformity

Related papers

Back to paper searchBrowse research topicsOriginal source
Complications related to an Interlaminar Fixation Device supplemented to Transarticular Screw Fixation of Atlantoaxial Joint — Research Paper | ScholarLens