2001Journal of Spinal DisordersRequires access

Morphologic and Radiologic Anatomy of the Occipital Bone

Sait Naderi, Can Usal, Ahmet N. Tural, Esin Korman, Tansu Mertol, Mehmet Nuri Arda

Open publisher page 21 citations

Abstract

Several diseases may cause craniovertebral instability warranting occiput-cervical fusion. As occipital screw and rod constructs are becoming more popular, requiring that screws be placed either medially or laterally in the occipital bone, the need for clearer anatomical and computed tomography (CT)-confirmed data regarding the relative thickness of the occiput in its various localities has become more critical. In 18 cadaveric specimens, the occipital bone was divided into 35 measurable segments. Transversely, the occipital bone was divided into five lines starting at the level of the inion; horizontal lines then proceeded inferiorly in 1-cm segments, 1, 2, 3, and 4 cm below the level of inion. In a comparable fashion, the occipital bone was divided vertically, starting at the midline, and proceeding laterally also in 1-, 2-, and 3-cm segments. Anatomical measurements of thickness were directly performed using a Vernier caliper. Results were directly correlated with axial CT measurements of bony thickness. Anatomical and CT measurements closely correlated within the same specimen, but there was significant interspecimen variability. The marked differences in the occipital bone anatomy noted between specimens indicates that patients undergoing occipital screw placement for cranial-cervical instability would benefit from preoperative occipital CT evaluations.

About this research paper

What this paper is about

Several diseases may cause craniovertebral instability warranting occiput-cervical fusion. As occipital screw and rod constructs are becoming more popular, requiring that screws be placed either medially or laterally in the occipital bone, the need for clearer anatomical and computed tomography (CT)-confirmed data regarding the relative thickness of the occiput in its various localities has become more critical. In 18 cadaveric specimens, the occipital bone was divided into 35 measurable segments. Transversely, the occipital bone was divided into five lines starting at the level of the inion; horizontal lines then proceeded inferiorly in 1-cm segments, 1, 2, 3, and 4 cm below the level of inion. In a comparable fashion, the occipital bone was divided vertically, starting at the midline, and proceeding laterally also in 1-, 2-, and 3-cm segments. Anatomical measurements of thickness were directly performed using a Vernier caliper. Results were directly correlated with axial CT measurements of bony thickness. Anatomical and CT measurements closely correlated within the same specimen, but there was significant interspecimen variability. The marked differences in the occipital bone anatomy noted between specimens indicates that patients undergoing occipital screw placement for cranial-cervical instability would benefit from preoperative occipital CT evaluations.

Why it matters

OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Several diseases may cause craniovertebral instability warranting occiput-cervical fusion. As occipital screw and rod constructs are becoming more popular, requiring that screws be placed either medially or laterally in the occipital bone, the need for clearer anatomical and computed tomography (CT)-confirmed data regarding the relative thickness of the occiput in its various localities has become more critical. In 18 cadaveric specimens, the occipital bone was divided into 35 measurable segments. Transversely, the occipital bone was divided into five lines starting at the level of the inion; horizontal lines then proceeded inferiorly in 1-cm segments, 1, 2, 3, and 4 cm below the level of inion. In a comparable fashion, the occipital bone was divided vertically, starting at the midline, and proceeding laterally also in 1-, 2-, and 3-cm segments. Anatomical measurements of thickness were directly performed using a Vernier caliper. Results were directly correlated with axial CT measurements of bony thickness. Anatomical and CT measurements closely correlated within the same specimen, but there was significant interspecimen variability. The marked differences in the occipital bone anatomy noted between specimens indicates that patients undergoing occipital screw placement for cranial-cervical instability would benefit from preoperative occipital CT evaluations.

Key concepts: Occipital bone, Occiput, Calipers, Cadaveric spasm, Medicine, Anatomy, Occipital condyle, Cervical vertebrae

Related papers

Back to paper searchBrowse research topicsOriginal source
Morphologic and Radiologic Anatomy of the Occipital Bone — Research Paper | ScholarLens