2001BUNSEKI KAGAKUOpen access

Determination of ammonia by solid-phase spectrophotometry.

Yoshiaki MINAMIYA, Isoshi Nukatsuka, Kunio Ohzeki

Open full text 3 citations

Abstract

A simple, rapid and highly sensitive method was developed for the determination of trace amounts of ammonia. The method is based on the following steps: (1) ammonia is oxidized to nitrite ion with sodium hypochlorite in the presence of potassium bromide in an alkaline media; (2) the effect of remaining hypochlorite is masked by the addition of acetone; (3) the ion is reacted with sulfanilamide and N-1-naphthylethylenediamine in an acidic media; (4) the resulting reddish-purple compound is concentrated and fixed on a finely ground cation-exchange resin by batch operation; (5) the resin particles are filtered through a membrane filter in the presence of Zephiramine, leaving a colored thin-layer disc on the filter; and (6) the absorbance of this thin layer is measured directly with a spectrophotometer (545 nm). A calibration graph of good linearity was obtained up to 1.0 μg ammonia in a 10 ml of sample solution when the resin phase absorbance was measured against a resin thin layer, while linearity up to 0.8 μg of ammonia was obtained when the resin-phase absorbance was measured against a membrane filter. The detection limit was 5.3 ng (n=5) and 24.0 ng (n=5) in a 10 ml sample solution, respectively. The proposed method was applied to the determination of ammonia in a riverwater sample. Recoveries of 93.6∼107% were obtained.

Open-access reader

About this research paper

What this paper is about

A simple, rapid and highly sensitive method was developed for the determination of trace amounts of ammonia. The method is based on the following steps: (1) ammonia is oxidized to nitrite ion with sodium hypochlorite in the presence of potassium bromide in an alkaline media; (2) the effect of remaining hypochlorite is masked by the addition of acetone; (3) the ion is reacted with sulfanilamide and N-1-naphthylethylenediamine in an acidic media; (4) the resulting reddish-purple compound is concentrated and fixed on a finely ground cation-exchange resin by batch operation; (5) the resin particles are filtered through a membrane filter in the presence of Zephiramine, leaving a colored thin-layer disc on the filter; and (6) the absorbance of this thin layer is measured directly with a spectrophotometer (545 nm). A calibration graph of good linearity was obtained up to 1.0 μg ammonia in a 10 ml of sample solution when the resin phase absorbance was measured against a resin thin layer, while linearity up to 0.8 μg of ammonia was obtained when the resin-phase absorbance was measured against a membrane filter. The detection limit was 5.3 ng (n=5) and 24.0 ng (n=5) in a 10 ml sample solution, respectively. The proposed method was applied to the determination of ammonia in a riverwater sample. Recoveries of 93.6∼107% were obtained.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, rapid and highly sensitive method was developed for the determination of trace amounts of ammonia. The method is based on the following steps: (1) ammonia is oxidized to nitrite ion with sodium hypochlorite in the presence of potassium bromide in an alkaline media; (2) the effect of remaining hypochlorite is masked by the addition of acetone; (3) the ion is reacted with sulfanilamide and N-1-naphthylethylenediamine in an acidic media; (4) the resulting reddish-purple compound is concentrated and fixed on a finely ground cation-exchange resin by batch operation; (5) the resin particles are filtered through a membrane filter in the presence of Zephiramine, leaving a colored thin-layer disc on the filter; and (6) the absorbance of this thin layer is measured directly with a spectrophotometer (545 nm). A calibration graph of good linearity was obtained up to 1.0 μg ammonia in a 10 ml of sample solution when the resin phase absorbance was measured against a resin thin layer, while linearity up to 0.8 μg of ammonia was obtained when the resin-phase absorbance was measured against a membrane filter. The detection limit was 5.3 ng (n=5) and 24.0 ng (n=5) in a 10 ml sample solution, respectively. The proposed method was applied to the determination of ammonia in a riverwater sample. Recoveries of 93.6∼107% were obtained.

Key concepts: Absorbance, Chemistry, Detection limit, Spectrophotometry, Calibration curve, Ammonia, Chromatography, Hypochlorite

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of ammonia by solid-phase spectrophotometry. — Research Paper | ScholarLens