Methylthio‐substituted coumarin‐based fluorescent probe for highly specific and fast detection of hypochlorite and bioimaging application
Baijun Zhao, Wenwen Wang, Yanxi Song, Hongqi Li, Lin Jiang, Lingling Chu
Abstract
Baijun Zhao, Wenwen Wang, Yanxi Song, Hongqi Li, Lin Jiang, Lingling Chu
Abstract
Abstract Hypochlorite is a kind of endogenously produced reactive oxygen species (ROS) in the human immune system and plays a crucial role in many pathophysiological processes. In this work a novel fluorescent probe derived from 6‐methylthio coumarin was designed and synthesised for detection of hypochlorite in acetonitrile/phosphate‐buffered saline (MeCN/PBS) (1:1, v/v, pH 7.4) medium. The probe displayed high specificity toward hypochlorite over other ROS analytes, rapid response to hypochlorite within 30 s, and a broad applicable range of pH 3–8. The detection limit was calculated to be 1.48 μM. Application of this probe for in vitro Hecat cell imaging to detect hypochlorite ions was confirmed. A sensing mechanism based on thioether to sulfoxide oxidation by hypochlorite was proposed and demonstrated. The study presented an effective approach for construction of highly efficient hypochlorite chemosensors from hydrophilic methylthio‐substituted coumarins considering their facile access.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstract Hypochlorite is a kind of endogenously produced reactive oxygen species (ROS) in the human immune system and plays a crucial role in many pathophysiological processes. In this work a novel fluorescent probe derived from 6‐methylthio coumarin was designed and synthesised for detection of hypochlorite in acetonitrile/phosphate‐buffered saline (MeCN/PBS) (1:1, v/v, pH 7.4) medium. The probe displayed high specificity toward hypochlorite over other ROS analytes, rapid response to hypochlorite within 30 s, and a broad applicable range of pH 3–8. The detection limit was calculated to be 1.48 μM. Application of this probe for in vitro Hecat cell imaging to detect hypochlorite ions was confirmed. A sensing mechanism based on thioether to sulfoxide oxidation by hypochlorite was proposed and demonstrated. The study presented an effective approach for construction of highly efficient hypochlorite chemosensors from hydrophilic methylthio‐substituted coumarins considering their facile access.
Key concepts: Hypochlorite, Chemistry, Fluorescence, Detection limit, Hypochlorous acid, Analyte, Coumarin, Combinatorial chemistry