2014•Unpublished venueOpen access

The effect of DC superimposed AC voltage on partial discharges in dielectric bounded cavities

Pål Keim Olsen, Frank Mauseth, Erling Ildstad

Open full text 21 citations

Abstract

Voltage source converters is used in HVDC stations in offshore HVDC transmission systems, between the AC and DC power grid. The AC ripple voltage on the DC side of the HVDC stations can be in the range of 1-10 % of the nominal DC voltage, depending on the size of the filter employed. For offshore HVDC grids, there is a drive to use polymeric insulated cables on the DC side. This work investigates how an AC voltage at power frequency superimposed on DC voltage influence the partial discharge magnitude and repetition rate in artificial cylindrical cavities in polymeric insulation. The AC voltage is kept below the AC partial discharge extinction voltage, and the DC voltage is kept above the DC partial discharge inception voltage. A resistor-capacitor ABC-circuit model is used for prediction of partial discharge magnitude and repetition rate under combined AC and DC voltage. Measurements has been performed on a test object of 3 layers of PET film with 1 mm radius cylindrical cavity in the middle layer. The results indicate that an AC voltage ripple with an amplitude lower than the AC partial discharge extinction voltage will increase the number of large discharges, compared to a DC voltage without ripple, but the repetition rate will be several orders lower than the AC voltage frequency.

About this research paper

What this paper is about

Voltage source converters is used in HVDC stations in offshore HVDC transmission systems, between the AC and DC power grid. The AC ripple voltage on the DC side of the HVDC stations can be in the range of 1-10 % of the nominal DC voltage, depending on the size of the filter employed. For offshore HVDC grids, there is a drive to use polymeric insulated cables on the DC side. This work investigates how an AC voltage at power frequency superimposed on DC voltage influence the partial discharge magnitude and repetition rate in artificial cylindrical cavities in polymeric insulation. The AC voltage is kept below the AC partial discharge extinction voltage, and the DC voltage is kept above the DC partial discharge inception voltage. A resistor-capacitor ABC-circuit model is used for prediction of partial discharge magnitude and repetition rate under combined AC and DC voltage. Measurements has been performed on a test object of 3 layers of PET film with 1 mm radius cylindrical cavity in the middle layer. The results indicate that an AC voltage ripple with an amplitude lower than the AC partial discharge extinction voltage will increase the number of large discharges, compared to a DC voltage without ripple, but the repetition rate will be several orders lower than the AC voltage frequency.

Why it matters

OpenAlex reports 21 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Voltage source converters is used in HVDC stations in offshore HVDC transmission systems, between the AC and DC power grid. The AC ripple voltage on the DC side of the HVDC stations can be in the range of 1-10 % of the nominal DC voltage, depending on the size of the filter employed. For offshore HVDC grids, there is a drive to use polymeric insulated cables on the DC side. This work investigates how an AC voltage at power frequency superimposed on DC voltage influence the partial discharge magnitude and repetition rate in artificial cylindrical cavities in polymeric insulation. The AC voltage is kept below the AC partial discharge extinction voltage, and the DC voltage is kept above the DC partial discharge inception voltage. A resistor-capacitor ABC-circuit model is used for prediction of partial discharge magnitude and repetition rate under combined AC and DC voltage. Measurements has been performed on a test object of 3 layers of PET film with 1 mm radius cylindrical cavity in the middle layer. The results indicate that an AC voltage ripple with an amplitude lower than the AC partial discharge extinction voltage will increase the number of large discharges, compared to a DC voltage without ripple, but the repetition rate will be several orders lower than the AC voltage frequency.

Key concepts: Partial discharge, Voltage, Materials science, Ripple, Electrical engineering, Capacitor, Voltage doubler, Pre-charge

Related papers

Back to paper searchBrowse research topicsOriginal source
The effect of DC superimposed AC voltage on partial discharges in dielectric bounded cavities — Research Paper | ScholarLens