1998•Anesthesia & AnalgesiaRequires access

0.125% Ropivacaine Is Similar to 0.125% Bupivacaine for Labor Analgesia Using Patient-Controlled Epidural Infusion

Medge D. Owen, Robert DʼAngelo, J. C. Gerancher, John McLean Thompson, Michael L. Foss, Jeffrey D. Babb, James C. Eisenach

Open publisher page 128 citations

Abstract

UNLABELLED: We compared the effects of 0.125% ropivacaine with 0.125% bupivacaine in laboring patients using patient-controlled epidural analgesia (PCEA). Fifty-one ASA physical status I or II term parturients with functioning epidural catheters were randomized to receive ropivacaine or bupivacaine using a prospective, double-blind design. Basal infusions (6 mL/h) were supplemented with patient-controlled boluses (5 mL) every 10 min as required. For inadequate analgesia, patients were administered 10-mL boluses of study solution until comfortable. There were no differences in verbal pain scores, amount of local anesthetics used, sensory levels, motor blockade, labor duration, mode of delivery, side effects, or patient satisfaction between the two local anesthetics. We conclude that 0.125% ropivacaine and bupivacaine are clinically indistinguishable and are both highly effective for labor analgesia using PCEA. IMPLICATIONS: This study compared labor analgesia from 0.125% ropivacaine and 0.125% bupivacaine using patient-controlled epidural analgesia. We found no significant differences in local anesthetic use, analgesic characteristics, or side effects between 0.125% ropivacaine and 0.125% bupivacaine. We conclude that these two drugs are clinically indistinguishable at this concentration.

About this research paper

What this paper is about

UNLABELLED: We compared the effects of 0.125% ropivacaine with 0.125% bupivacaine in laboring patients using patient-controlled epidural analgesia (PCEA). Fifty-one ASA physical status I or II term parturients with functioning epidural catheters were randomized to receive ropivacaine or bupivacaine using a prospective, double-blind design. Basal infusions (6 mL/h) were supplemented with patient-controlled boluses (5 mL) every 10 min as required. For inadequate analgesia, patients were administered 10-mL boluses of study solution until comfortable. There were no differences in verbal pain scores, amount of local anesthetics used, sensory levels, motor blockade, labor duration, mode of delivery, side effects, or patient satisfaction between the two local anesthetics. We conclude that 0.125% ropivacaine and bupivacaine are clinically indistinguishable and are both highly effective for labor analgesia using PCEA. IMPLICATIONS: This study compared labor analgesia from 0.125% ropivacaine and 0.125% bupivacaine using patient-controlled epidural analgesia. We found no significant differences in local anesthetic use, analgesic characteristics, or side effects between 0.125% ropivacaine and 0.125% bupivacaine. We conclude that these two drugs are clinically indistinguishable at this concentration.

Why it matters

OpenAlex reports 128 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

UNLABELLED: We compared the effects of 0.125% ropivacaine with 0.125% bupivacaine in laboring patients using patient-controlled epidural analgesia (PCEA). Fifty-one ASA physical status I or II term parturients with functioning epidural catheters were randomized to receive ropivacaine or bupivacaine using a prospective, double-blind design. Basal infusions (6 mL/h) were supplemented with patient-controlled boluses (5 mL) every 10 min as required. For inadequate analgesia, patients were administered 10-mL boluses of study solution until comfortable. There were no differences in verbal pain scores, amount of local anesthetics used, sensory levels, motor blockade, labor duration, mode of delivery, side effects, or patient satisfaction between the two local anesthetics. We conclude that 0.125% ropivacaine and bupivacaine are clinically indistinguishable and are both highly effective for labor analgesia using PCEA. IMPLICATIONS: This study compared labor analgesia from 0.125% ropivacaine and 0.125% bupivacaine using patient-controlled epidural analgesia. We found no significant differences in local anesthetic use, analgesic characteristics, or side effects between 0.125% ropivacaine and 0.125% bupivacaine. We conclude that these two drugs are clinically indistinguishable at this concentration.

Key concepts: Medicine, Ropivacaine, Bupivacaine, Anesthesia, Continuous infusion

Related papers

Back to paper searchBrowse research topicsOriginal source
0.125% Ropivacaine Is Similar to 0.125% Bupivacaine for Labor Analgesia Using Patient-Controlled Epidural Infusion — Research Paper | ScholarLens