2011Bulletin of the Korean Chemical SocietyOpen access

A Correction Method for the Peak Tailing Backgrounds for Accurate Isotope Ratio Measurements of Uranium in Ultra Trace Levels using Thermal Ionization Mass Spectrometry

Jong‐Ho Park, Inhee Choi, Su-Jin Park, Myung-Ho Lee, Kyu-Seok Song

Open full text 12 citations

Abstract

A new method in thermal ionization mass spectrometry (TIMS) was developed to correct peak tailing backgrounds in the isotope ratio measurements of uranium in ultra trace levels for higher accuracy. Two different uranium standard reference materials (U005 and U030) were used to construct databases of signal intensities at mass 234 u and mass 236 u, which correspond to the two uranium minor isotopes, and signal intensity of $^{238}U$ . Correlations between peak tailing backgrounds and $^{238}U$ were obtained by least-squares regression on calculated backgrounds at mass 234 u and mass 236 u with respect to the signal intensity of $^{238}U$ followed by separation of the peak tails of the two major isotopes of uranium ( $^{235}U$ and $^{238}U$ ), which enables us to obtain a master equation for peak tailing background correction on all kinds of samples. Verification of the correction method was carried out using U010 and IRMM-040a.

Open-access reader

About this research paper

What this paper is about

A new method in thermal ionization mass spectrometry (TIMS) was developed to correct peak tailing backgrounds in the isotope ratio measurements of uranium in ultra trace levels for higher accuracy. Two different uranium standard reference materials (U005 and U030) were used to construct databases of signal intensities at mass 234 u and mass 236 u, which correspond to the two uranium minor isotopes, and signal intensity of $^{238}U$ . Correlations between peak tailing backgrounds and $^{238}U$ were obtained by least-squares regression on calculated backgrounds at mass 234 u and mass 236 u with respect to the signal intensity of $^{238}U$ followed by separation of the peak tails of the two major isotopes of uranium ( $^{235}U$ and $^{238}U$ ), which enables us to obtain a master equation for peak tailing background correction on all kinds of samples. Verification of the correction method was carried out using U010 and IRMM-040a.

Why it matters

OpenAlex reports 12 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new method in thermal ionization mass spectrometry (TIMS) was developed to correct peak tailing backgrounds in the isotope ratio measurements of uranium in ultra trace levels for higher accuracy. Two different uranium standard reference materials (U005 and U030) were used to construct databases of signal intensities at mass 234 u and mass 236 u, which correspond to the two uranium minor isotopes, and signal intensity of $^{238}U$ . Correlations between peak tailing backgrounds and $^{238}U$ were obtained by least-squares regression on calculated backgrounds at mass 234 u and mass 236 u with respect to the signal intensity of $^{238}U$ followed by separation of the peak tails of the two major isotopes of uranium ( $^{235}U$ and $^{238}U$ ), which enables us to obtain a master equation for peak tailing background correction on all kinds of samples. Verification of the correction method was carried out using U010 and IRMM-040a.

Key concepts: Uranium, Thermal ionization mass spectrometry, Isotopes of uranium, Isotope, Thermal ionization, Chemistry, Mass spectrometry, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
A Correction Method for the Peak Tailing Backgrounds for Accurate Isotope Ratio Measurements of Uranium in Ultra Trace Levels using Thermal Ionization Mass Spectrometry — Research Paper | ScholarLens