2013Bulletin of the Korean Chemical SocietyOpen access

Rapid Determination of Ginkgolic Acids in Ginkgo biloba Leaf Using Online Column Switching High-Performance Liquid Chromatography-Diode Array Detection and Confirmation by Liquid Chromatography-tandem Mass Spectrometry

Hyounyoung Lee, Heung-Youl Lim, Juhong Yang, Jongki Hong

Open full text 13 citations

Abstract

In this study, an improved method for the quantitative analysis of ginkgolic acids (GAs) in Ginkgo biloba leaf extract was developed. The samples were extracted with a mixture of chloroform and 50 % ethanol, after which the chloroform extract was dried and reconstituted in methanol. GAs with 13:0, 15:1, and 17:1 in the extract were successfully separated within 40 min and determined with high throughput performance using an online column-switching HPLC method using an SP column C8 SG80 ( $4.6{\times}150mm$ , $5{\mu}m$ ) and a Cadenza 5CD C18 column ( $4.6{\times}150mm$ , $3{\mu}m$ ). The developed HPLC method was validated for Ginkgo biloba leaf extract. The validation parameters were specificity, linearity, precision, accuracy, and limits of detection and quantitation (LODs and LOQs, respectively). It was found that all of the calibration curves showed good linearity ( $r^2$ > 0.9993) within the tested ranges. The LODs and LOQs were all lower than $0.04{\mu}g/mL$ . The established method was found to be simple, rapid, and high throughput for the quantitative analysis of GAs in ten commercial Ginkgo biloba leaf extract and dietary supplements. The samples were also analyzed in LC-electrospray ionization (ESI) tandem mass spectrometry (MS/MS) - multiple-ion reaction monitoring (MRM) mode to confirm the identification results that were obtained by the column switching HPLC-DAD method. The developed method is considered to be suitable for the routine quality control and safety assurance of Ginkgo biloba leaf extract.

Open-access reader

About this research paper

What this paper is about

In this study, an improved method for the quantitative analysis of ginkgolic acids (GAs) in Ginkgo biloba leaf extract was developed. The samples were extracted with a mixture of chloroform and 50 % ethanol, after which the chloroform extract was dried and reconstituted in methanol. GAs with 13:0, 15:1, and 17:1 in the extract were successfully separated within 40 min and determined with high throughput performance using an online column-switching HPLC method using an SP column C8 SG80 ( $4.6{\times}150mm$ , $5{\mu}m$ ) and a Cadenza 5CD C18 column ( $4.6{\times}150mm$ , $3{\mu}m$ ). The developed HPLC method was validated for Ginkgo biloba leaf extract. The validation parameters were specificity, linearity, precision, accuracy, and limits of detection and quantitation (LODs and LOQs, respectively). It was found that all of the calibration curves showed good linearity ( $r^2$ > 0.9993) within the tested ranges. The LODs and LOQs were all lower than $0.04{\mu}g/mL$ . The established method was found to be simple, rapid, and high throughput for the quantitative analysis of GAs in ten commercial Ginkgo biloba leaf extract and dietary supplements. The samples were also analyzed in LC-electrospray ionization (ESI) tandem mass spectrometry (MS/MS) - multiple-ion reaction monitoring (MRM) mode to confirm the identification results that were obtained by the column switching HPLC-DAD method. The developed method is considered to be suitable for the routine quality control and safety assurance of Ginkgo biloba leaf extract.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this study, an improved method for the quantitative analysis of ginkgolic acids (GAs) in Ginkgo biloba leaf extract was developed. The samples were extracted with a mixture of chloroform and 50 % ethanol, after which the chloroform extract was dried and reconstituted in methanol. GAs with 13:0, 15:1, and 17:1 in the extract were successfully separated within 40 min and determined with high throughput performance using an online column-switching HPLC method using an SP column C8 SG80 ( $4.6{\times}150mm$ , $5{\mu}m$ ) and a Cadenza 5CD C18 column ( $4.6{\times}150mm$ , $3{\mu}m$ ). The developed HPLC method was validated for Ginkgo biloba leaf extract. The validation parameters were specificity, linearity, precision, accuracy, and limits of detection and quantitation (LODs and LOQs, respectively). It was found that all of the calibration curves showed good linearity ( $r^2$ > 0.9993) within the tested ranges. The LODs and LOQs were all lower than $0.04{\mu}g/mL$ . The established method was found to be simple, rapid, and high throughput for the quantitative analysis of GAs in ten commercial Ginkgo biloba leaf extract and dietary supplements. The samples were also analyzed in LC-electrospray ionization (ESI) tandem mass spectrometry (MS/MS) - multiple-ion reaction monitoring (MRM) mode to confirm the identification results that were obtained by the column switching HPLC-DAD method. The developed method is considered to be suitable for the routine quality control and safety assurance of Ginkgo biloba leaf extract.

Key concepts: Chromatography, Chemistry, Ginkgo biloba, Tandem mass spectrometry, Mass spectrometry, High-performance liquid chromatography, Electrospray ionization, Calibration curve

Related papers

Back to paper searchBrowse research topicsOriginal source
Rapid Determination of Ginkgolic Acids in Ginkgo biloba Leaf Using Online Column Switching High-Performance Liquid Chromatography-Diode Array Detection and Confirmation by Liquid Chromatography-tandem Mass Spectrometry — Research Paper | ScholarLens