1993•Geotechnical Testing JournalRequires access

Bearing Capacity of Strip Foundation on Geogrid-Reinforced Clay

EC Shin, BM Das, VK Puri, S.C. Yen, E.E. Cook

Open publisher page 85 citations

Abstract

Abstract Laboratory model test results are presented for the ultimate bearing capacity of a strip foundation supported by a saturated clay layer reinforced by layers of geogrid. The tests were conducted in one type of clay. The average moisture content of the clay was varied, yielding varying undrained shear strengths. Laboratory tests were conducted to determine the critical nondimensional values for the depth and width of the geogrid reinforcement layers and also the location of the first layer of geogrid with respect to the bottom of the foundation to obtain the maximum possible bearing capacity ratio.

About this research paper

What this paper is about

Abstract Laboratory model test results are presented for the ultimate bearing capacity of a strip foundation supported by a saturated clay layer reinforced by layers of geogrid. The tests were conducted in one type of clay. The average moisture content of the clay was varied, yielding varying undrained shear strengths. Laboratory tests were conducted to determine the critical nondimensional values for the depth and width of the geogrid reinforcement layers and also the location of the first layer of geogrid with respect to the bottom of the foundation to obtain the maximum possible bearing capacity ratio.

Why it matters

OpenAlex reports 85 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract Laboratory model test results are presented for the ultimate bearing capacity of a strip foundation supported by a saturated clay layer reinforced by layers of geogrid. The tests were conducted in one type of clay. The average moisture content of the clay was varied, yielding varying undrained shear strengths. Laboratory tests were conducted to determine the critical nondimensional values for the depth and width of the geogrid reinforcement layers and also the location of the first layer of geogrid with respect to the bottom of the foundation to obtain the maximum possible bearing capacity ratio.

Key concepts: Geogrid, Geotechnical engineering, Bearing capacity, Foundation (evidence), Shear strength (soil), Reinforcement, Geology, Water content

Related papers

Back to paper searchBrowse research topicsOriginal source
Bearing Capacity of Strip Foundation on Geogrid-Reinforced Clay — Research Paper | ScholarLens