1989•Survey of AnesthesiologyRequires access

Hydroxyethyl Starch

Christopher M. Munsch, Elizabeth A. Macintyre, Samuel J. Machin, Ian J. Mackie, Tom Treasure

Open publisher page 0 citations

Abstract

Comment This is a nicely performed study comparing tests of coagulation in patients receiving hydroxyethyl starch (HES) or plasma protein fraction (PPF). When used postoperatively in moderate amounts (500 to 1,500 ml), HES did not alter clotting or cause apparent side effects, and the authors conclude that HES is a useful alternative to PPF when volume expansion is needed. This study does not discuss the merits of using either of these solutions over other available plasma expanders. Albumin is free of some of the trace proteins which may cause occasional adverse reactions seen with PPF, and isotonic crystalloid solutions are less expensive if cost is the major concern. HES has also been reported to cause occasional allergic reactions and can result in bleeding problems if large amounts (usually more than 2,000 ml in an adult) are administered. In addition, the persistence of HES in the vascular and reticuloendothelial systems has raised at least theoretical concerns, particularly in children. Despite this report, I fail to see why either HES or PPF should be used instead of other commercially available solutions. Mark A. Rockoff, M.D.

About this research paper

What this paper is about

Comment This is a nicely performed study comparing tests of coagulation in patients receiving hydroxyethyl starch (HES) or plasma protein fraction (PPF). When used postoperatively in moderate amounts (500 to 1,500 ml), HES did not alter clotting or cause apparent side effects, and the authors conclude that HES is a useful alternative to PPF when volume expansion is needed. This study does not discuss the merits of using either of these solutions over other available plasma expanders. Albumin is free of some of the trace proteins which may cause occasional adverse reactions seen with PPF, and isotonic crystalloid solutions are less expensive if cost is the major concern. HES has also been reported to cause occasional allergic reactions and can result in bleeding problems if large amounts (usually more than 2,000 ml in an adult) are administered. In addition, the persistence of HES in the vascular and reticuloendothelial systems has raised at least theoretical concerns, particularly in children. Despite this report, I fail to see why either HES or PPF should be used instead of other commercially available solutions. Mark A. Rockoff, M.D.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Comment This is a nicely performed study comparing tests of coagulation in patients receiving hydroxyethyl starch (HES) or plasma protein fraction (PPF). When used postoperatively in moderate amounts (500 to 1,500 ml), HES did not alter clotting or cause apparent side effects, and the authors conclude that HES is a useful alternative to PPF when volume expansion is needed. This study does not discuss the merits of using either of these solutions over other available plasma expanders. Albumin is free of some of the trace proteins which may cause occasional adverse reactions seen with PPF, and isotonic crystalloid solutions are less expensive if cost is the major concern. HES has also been reported to cause occasional allergic reactions and can result in bleeding problems if large amounts (usually more than 2,000 ml in an adult) are administered. In addition, the persistence of HES in the vascular and reticuloendothelial systems has raised at least theoretical concerns, particularly in children. Despite this report, I fail to see why either HES or PPF should be used instead of other commercially available solutions. Mark A. Rockoff, M.D.

Key concepts: Hydroxyethyl starch, Medicine, Albumin, Plasma volume, Intravascular volume status, Isotonic, Anesthesia, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
Hydroxyethyl Starch — Research Paper | ScholarLens