1997Acta Ophthalmologica ScandinavicaRequires access

Value of intraoperative keratometry in predicting outcome of radial keratotomy

Hanne Olsen, Niels Ehlers, Jesper Hjortdal

Open publisher page 3 citations

Abstract

PURPOSE: To investigate whether the immediate change in corneal power during radial keratotomy correlates with the long-term postoperative change in subjective refraction, and thereby being predictive for refractive outcome. METHODS: Manual keratometry was performed on 45 consecutively operated eyes of 45 young persons with myopia of 5 dioptres and less and immediately after radial keratotomy. Automated keratometry and subjective spherical equivalent refraction were investigated during a follow-up period of 6 months and correlated to the intraoperative keratometric measurements. RESULTS: On average, the majority of the change in corneal curvature after radial keratotomy took place within 1 min. There was no correlation between the intraoperative curvature change and the changes in curvature measured up to 6 months after surgery. There was a weak significant positive correlation between intraoperative curvature change and the change in subjective refraction at 6 months after surgery (R = 0.48, p < 0.01). The prediction error in estimating subjective refractive changes from intraoperative keratometry changes was, however, similar in patients who had bilateral radial keratotomy. Inclusion of such fellow-eye information together with the age of the patient in a multiple linear regression analysis increased the correlation coefficient from 0.48 to 0.75. CONCLUSIONS: The change in central corneal curvature takes place within minutes after corneal incision. As a single parameter, intraoperative keratometry cannot be used for titrating surgery. Information from the results of first eye radial keratotomy surgery with intraoperative keratometry is, however, predictive for radial keratotomy in the second eye. These findings suggest that a large source to refractive variability after radial keratotomy is related to individual patient factors, such as corneal biomechanics and wound healing.

About this research paper

What this paper is about

PURPOSE: To investigate whether the immediate change in corneal power during radial keratotomy correlates with the long-term postoperative change in subjective refraction, and thereby being predictive for refractive outcome. METHODS: Manual keratometry was performed on 45 consecutively operated eyes of 45 young persons with myopia of 5 dioptres and less and immediately after radial keratotomy. Automated keratometry and subjective spherical equivalent refraction were investigated during a follow-up period of 6 months and correlated to the intraoperative keratometric measurements. RESULTS: On average, the majority of the change in corneal curvature after radial keratotomy took place within 1 min. There was no correlation between the intraoperative curvature change and the changes in curvature measured up to 6 months after surgery. There was a weak significant positive correlation between intraoperative curvature change and the change in subjective refraction at 6 months after surgery (R = 0.48, p < 0.01). The prediction error in estimating subjective refractive changes from intraoperative keratometry changes was, however, similar in patients who had bilateral radial keratotomy. Inclusion of such fellow-eye information together with the age of the patient in a multiple linear regression analysis increased the correlation coefficient from 0.48 to 0.75. CONCLUSIONS: The change in central corneal curvature takes place within minutes after corneal incision. As a single parameter, intraoperative keratometry cannot be used for titrating surgery. Information from the results of first eye radial keratotomy surgery with intraoperative keratometry is, however, predictive for radial keratotomy in the second eye. These findings suggest that a large source to refractive variability after radial keratotomy is related to individual patient factors, such as corneal biomechanics and wound healing.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To investigate whether the immediate change in corneal power during radial keratotomy correlates with the long-term postoperative change in subjective refraction, and thereby being predictive for refractive outcome. METHODS: Manual keratometry was performed on 45 consecutively operated eyes of 45 young persons with myopia of 5 dioptres and less and immediately after radial keratotomy. Automated keratometry and subjective spherical equivalent refraction were investigated during a follow-up period of 6 months and correlated to the intraoperative keratometric measurements. RESULTS: On average, the majority of the change in corneal curvature after radial keratotomy took place within 1 min. There was no correlation between the intraoperative curvature change and the changes in curvature measured up to 6 months after surgery. There was a weak significant positive correlation between intraoperative curvature change and the change in subjective refraction at 6 months after surgery (R = 0.48, p < 0.01). The prediction error in estimating subjective refractive changes from intraoperative keratometry changes was, however, similar in patients who had bilateral radial keratotomy. Inclusion of such fellow-eye information together with the age of the patient in a multiple linear regression analysis increased the correlation coefficient from 0.48 to 0.75. CONCLUSIONS: The change in central corneal curvature takes place within minutes after corneal incision. As a single parameter, intraoperative keratometry cannot be used for titrating surgery. Information from the results of first eye radial keratotomy surgery with intraoperative keratometry is, however, predictive for radial keratotomy in the second eye. These findings suggest that a large source to refractive variability after radial keratotomy is related to individual patient factors, such as corneal biomechanics and wound healing.

Key concepts: Medicine, Radial keratotomy, Keratometer, Ophthalmology, Value (mathematics), Outcome (game theory), Optometry, Cornea

Related papers

Back to paper searchBrowse research topicsOriginal source
Value of intraoperative keratometry in predicting outcome of radial keratotomy — Research Paper | ScholarLens