1985Archives of OphthalmologyRequires access

A Study of Optical Zone Size and Incision Redeepening in Experimental Radial Keratotomy

James J. Salz, J. J. Rowsey, B. Elizabeth Caroline, Stanley P. Azen, Marc J.‐F. Suter, R. Monlux

Open publisher page 26 citations

Abstract

The effects of optical clear zone size and incision redeepening following four- and eight-incision radial keratotomy were studied in a series of human cadaver eyes. Keratometry was measured with both the Terry keratometer and corneascope photographs. After eight incisions, induced corneal flattening for each clear zone (Terry keratometry readings) was 3.0 mm, 9.06 diopters; 4.0 mm, 6.44 D; 5.0 mm, 5.23 D; and 6.0 mm, 2.29 D. Differences were statistically significant, except for the 4.0-mm and 5.0-mm zones. Induced corneal flattening following eight incisions (corneoscopy) was 3.0 mm, 9.83 D; 4.0 mm, 8.87 D; 5.0 mm, 6.04 D; and 6.0 mm, 2.59 D. Differences were statistically significant, except for the 3.0-mm and 4.0-mm zones. Peripheral redeepening of the incisions did not significantly increase the amount of corneal flattening for any optical zone, as measured by the Terry keratometer. However, the 3.0-mm optical zone flattened an additional 1.23 D after the redeepening incisions, as measured by corneoscopy. The redeepening incisions were complicated by perforations in 38% of the eyes. Titrating the effect of radial keratotomy by varying the size of the optical zone appears to be valid, but the value of peripheral redeepening in the acute laboratory situation is not supported by these data.

About this research paper

What this paper is about

The effects of optical clear zone size and incision redeepening following four- and eight-incision radial keratotomy were studied in a series of human cadaver eyes. Keratometry was measured with both the Terry keratometer and corneascope photographs. After eight incisions, induced corneal flattening for each clear zone (Terry keratometry readings) was 3.0 mm, 9.06 diopters; 4.0 mm, 6.44 D; 5.0 mm, 5.23 D; and 6.0 mm, 2.29 D. Differences were statistically significant, except for the 4.0-mm and 5.0-mm zones. Induced corneal flattening following eight incisions (corneoscopy) was 3.0 mm, 9.83 D; 4.0 mm, 8.87 D; 5.0 mm, 6.04 D; and 6.0 mm, 2.59 D. Differences were statistically significant, except for the 3.0-mm and 4.0-mm zones. Peripheral redeepening of the incisions did not significantly increase the amount of corneal flattening for any optical zone, as measured by the Terry keratometer. However, the 3.0-mm optical zone flattened an additional 1.23 D after the redeepening incisions, as measured by corneoscopy. The redeepening incisions were complicated by perforations in 38% of the eyes. Titrating the effect of radial keratotomy by varying the size of the optical zone appears to be valid, but the value of peripheral redeepening in the acute laboratory situation is not supported by these data.

Why it matters

OpenAlex reports 26 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The effects of optical clear zone size and incision redeepening following four- and eight-incision radial keratotomy were studied in a series of human cadaver eyes. Keratometry was measured with both the Terry keratometer and corneascope photographs. After eight incisions, induced corneal flattening for each clear zone (Terry keratometry readings) was 3.0 mm, 9.06 diopters; 4.0 mm, 6.44 D; 5.0 mm, 5.23 D; and 6.0 mm, 2.29 D. Differences were statistically significant, except for the 4.0-mm and 5.0-mm zones. Induced corneal flattening following eight incisions (corneoscopy) was 3.0 mm, 9.83 D; 4.0 mm, 8.87 D; 5.0 mm, 6.04 D; and 6.0 mm, 2.59 D. Differences were statistically significant, except for the 3.0-mm and 4.0-mm zones. Peripheral redeepening of the incisions did not significantly increase the amount of corneal flattening for any optical zone, as measured by the Terry keratometer. However, the 3.0-mm optical zone flattened an additional 1.23 D after the redeepening incisions, as measured by corneoscopy. The redeepening incisions were complicated by perforations in 38% of the eyes. Titrating the effect of radial keratotomy by varying the size of the optical zone appears to be valid, but the value of peripheral redeepening in the acute laboratory situation is not supported by these data.

Key concepts: Keratometer, Radial keratotomy, Dioptre, Ophthalmology, Flattening, Medicine, Cornea, Corneal topography

Related papers

Back to paper searchBrowse research topicsOriginal source
A Study of Optical Zone Size and Incision Redeepening in Experimental Radial Keratotomy — Research Paper | ScholarLens