2004•Journal of the IESTRequires access

Comparison of Indoor Environment of a Locally Concentrated Cleanroom at Occupied and Unoccupied Status by Numerical Method

Bin Zhao, Li Cao, Xianting Li, Xudong Yang, Dongtao Huang

Open publisher page 5 citations

Abstract

The existing standard for cleanrooms is based on an unoccupied state where there are no people or furniture inside the room. However, the distribution of airflow and particles in a cleanroom may differ significantly in an occupied state with the presence of people and furniture. This paper first validates a numerical model for simulating the air distribution in a locally concentrated cleanroom. Then the indoor airflow and the pollutant concentration in a locally concentrated bio-clean operation room (BCOR) are simulated at both occupied and unoccupied states by the validated model. The comparison of results shows the environment is very different between the two cases. Thus, human bodies and furniture should be properly considered when evaluating the environment in the locally concentrated cleanroom.

About this research paper

What this paper is about

The existing standard for cleanrooms is based on an unoccupied state where there are no people or furniture inside the room. However, the distribution of airflow and particles in a cleanroom may differ significantly in an occupied state with the presence of people and furniture. This paper first validates a numerical model for simulating the air distribution in a locally concentrated cleanroom. Then the indoor airflow and the pollutant concentration in a locally concentrated bio-clean operation room (BCOR) are simulated at both occupied and unoccupied states by the validated model. The comparison of results shows the environment is very different between the two cases. Thus, human bodies and furniture should be properly considered when evaluating the environment in the locally concentrated cleanroom.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The existing standard for cleanrooms is based on an unoccupied state where there are no people or furniture inside the room. However, the distribution of airflow and particles in a cleanroom may differ significantly in an occupied state with the presence of people and furniture. This paper first validates a numerical model for simulating the air distribution in a locally concentrated cleanroom. Then the indoor airflow and the pollutant concentration in a locally concentrated bio-clean operation room (BCOR) are simulated at both occupied and unoccupied states by the validated model. The comparison of results shows the environment is very different between the two cases. Thus, human bodies and furniture should be properly considered when evaluating the environment in the locally concentrated cleanroom.

Key concepts: Cleanroom, Airflow, Environmental science, Indoor air, Environmental engineering, Simulation, Engineering, Mechanical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of Indoor Environment of a Locally Concentrated Cleanroom at Occupied and Unoccupied Status by Numerical Method — Research Paper | ScholarLens