2004MetrologiaOpen access

Measurements of fibre optic power using photodiodes with and without an integrating sphere

Jouni Envall, Petri Kärhä, Erkki Ikonen

Open full text 17 citations

Abstract

We have studied two kinds of reference detectors to be used for calibration of fibre optic power meters. The first type consists of an InGaAs photodiode mounted directly on an adapter using a standard FC connector. In the second type, a similar photodiode is fitted into a 5 cm diameter integrating sphere. The plain photodiodes are used for low power levels and the sphere detector for high power levels because of the low throughput (∼0.7%) of the sphere. The detectors, with their FC connectors removed, are calibrated using collimated laser beams, using as the reference a spectrally flat pyroelectric radiometer traceable to a cryogenic absolute radiometer. The spatial non-uniformities of the plain photodiodes are of the order of 0.3% throughout the active area of 5 mm diameter. The angular responsivity varies less than ±0.1% within the angle of ±8°, which covers 99% of the radiation emitted from the fibre end. The angular non-uniformity of the sphere detector is less than 0.1%. The results indicate that a plain photodiode can be used as a reference detector of fibre optic power. The calibration uncertainty at HUT is presently of the order of 1% ( k = 2).

Open-access reader

About this research paper

What this paper is about

We have studied two kinds of reference detectors to be used for calibration of fibre optic power meters. The first type consists of an InGaAs photodiode mounted directly on an adapter using a standard FC connector. In the second type, a similar photodiode is fitted into a 5 cm diameter integrating sphere. The plain photodiodes are used for low power levels and the sphere detector for high power levels because of the low throughput (∼0.7%) of the sphere. The detectors, with their FC connectors removed, are calibrated using collimated laser beams, using as the reference a spectrally flat pyroelectric radiometer traceable to a cryogenic absolute radiometer. The spatial non-uniformities of the plain photodiodes are of the order of 0.3% throughout the active area of 5 mm diameter. The angular responsivity varies less than ±0.1% within the angle of ±8°, which covers 99% of the radiation emitted from the fibre end. The angular non-uniformity of the sphere detector is less than 0.1%. The results indicate that a plain photodiode can be used as a reference detector of fibre optic power. The calibration uncertainty at HUT is presently of the order of 1% ( k = 2).

Why it matters

OpenAlex reports 17 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have studied two kinds of reference detectors to be used for calibration of fibre optic power meters. The first type consists of an InGaAs photodiode mounted directly on an adapter using a standard FC connector. In the second type, a similar photodiode is fitted into a 5 cm diameter integrating sphere. The plain photodiodes are used for low power levels and the sphere detector for high power levels because of the low throughput (∼0.7%) of the sphere. The detectors, with their FC connectors removed, are calibrated using collimated laser beams, using as the reference a spectrally flat pyroelectric radiometer traceable to a cryogenic absolute radiometer. The spatial non-uniformities of the plain photodiodes are of the order of 0.3% throughout the active area of 5 mm diameter. The angular responsivity varies less than ±0.1% within the angle of ±8°, which covers 99% of the radiation emitted from the fibre end. The angular non-uniformity of the sphere detector is less than 0.1%. The results indicate that a plain photodiode can be used as a reference detector of fibre optic power. The calibration uncertainty at HUT is presently of the order of 1% ( k = 2).

Key concepts: Photodiode, Integrating sphere, Materials science, Power (physics), Optics, Optical power, Optical fiber, Optoelectronics

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurements of fibre optic power using photodiodes with and without an integrating sphere — Research Paper | ScholarLens