Determination of the antioxidant capacity in blood

Marc A. J. G. Fischer, Theo J. M. Gransier, Lenie M. G. Beckers, Otto Bekers, Aalt Bast, Guido R.M.M. Haenen

Open publisher page 89 citations

Abstract

BACKGROUND: A vast amount of scientific research is directed towards the beneficial effects of antioxidants on health. For this reason, several assays have been developed to determine the total antioxidant capacity of blood. METHODS: In this study two procedures based on the use of the green-blue 2,2'-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid) radical (ABTS(*+)) were compared. In the first (commercially available) procedure, ABTS(*+) was generated in the presence of the blood sample. In the second procedure, referred to as the decolorization assay, antioxidants react with preformed ABTS(*+). RESULTS: It was found that the first procedure leads to greater underestimation of the actual antioxidant capacity and is more prone to artifacts than the second procedure. Therefore, only the latter procedure was evaluated in detail and it appeared that (i) plasma is preferred over serum, (ii) the high background produced by albumin can be circumvented by deproteination, (iii) samples can be stored at -80 degrees C for 12 months, and (iv) the assay has high precision. Due to poor linearity, the procedure has to be standardized to allow sample comparison. CONCLUSIONS: The decolorization assay is a reliable and robust assay that can be applied routinely to predict the antioxidant capacity of blood.

About this research paper

What this paper is about

BACKGROUND: A vast amount of scientific research is directed towards the beneficial effects of antioxidants on health. For this reason, several assays have been developed to determine the total antioxidant capacity of blood. METHODS: In this study two procedures based on the use of the green-blue 2,2'-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid) radical (ABTS(*+)) were compared. In the first (commercially available) procedure, ABTS(*+) was generated in the presence of the blood sample. In the second procedure, referred to as the decolorization assay, antioxidants react with preformed ABTS(*+). RESULTS: It was found that the first procedure leads to greater underestimation of the actual antioxidant capacity and is more prone to artifacts than the second procedure. Therefore, only the latter procedure was evaluated in detail and it appeared that (i) plasma is preferred over serum, (ii) the high background produced by albumin can be circumvented by deproteination, (iii) samples can be stored at -80 degrees C for 12 months, and (iv) the assay has high precision. Due to poor linearity, the procedure has to be standardized to allow sample comparison. CONCLUSIONS: The decolorization assay is a reliable and robust assay that can be applied routinely to predict the antioxidant capacity of blood.

Why it matters

OpenAlex reports 89 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: A vast amount of scientific research is directed towards the beneficial effects of antioxidants on health. For this reason, several assays have been developed to determine the total antioxidant capacity of blood. METHODS: In this study two procedures based on the use of the green-blue 2,2'-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid) radical (ABTS(*+)) were compared. In the first (commercially available) procedure, ABTS(*+) was generated in the presence of the blood sample. In the second procedure, referred to as the decolorization assay, antioxidants react with preformed ABTS(*+). RESULTS: It was found that the first procedure leads to greater underestimation of the actual antioxidant capacity and is more prone to artifacts than the second procedure. Therefore, only the latter procedure was evaluated in detail and it appeared that (i) plasma is preferred over serum, (ii) the high background produced by albumin can be circumvented by deproteination, (iii) samples can be stored at -80 degrees C for 12 months, and (iv) the assay has high precision. Due to poor linearity, the procedure has to be standardized to allow sample comparison. CONCLUSIONS: The decolorization assay is a reliable and robust assay that can be applied routinely to predict the antioxidant capacity of blood.

Key concepts: ABTS, Antioxidant capacity, Antioxidant, Chemistry, Medicine, Food science, Biochemistry, Chromatography