2014IEEE Geoscience and Remote Sensing LettersRequires access

Retrieval Analysis of Atmospheric Water Vapor for K-Band Ground-Based Hyperspectral Microwave Radiometer

Dawei Liu, Changchun Lv, Kai Liu, Yan Xie, Jungang Miao

Open publisher page 13 citations

Abstract

In this letter, we study the performance of a K-band ground-based hyperspectral microwave radiometer for the observation of atmospheric water vapor. First, a prototype of a K-band ground-based hyperspectral microwave radiometer for atmospheric sounding is proposed. This microwave radiometer is able to split the 18-26-GHz signal into 80 hyperspectral channels with identical bandwidth. Simulation studies, including the retrieval performance of water vapor and the vertical resolution of observation compared with the five-humidity-channel radiometer TP/WVP-3000 under the same conditions, are presented to assess the capability of the prototype. Simulation results show that the vertical resolution of this prototype is better than that of TP/WVP-3000 at a higher altitude, and the RMS water vapor error improves by about 10% at an altitude of 0-6 km. Moreover, by simulation, we analyze the impact of the radiometer channel number on the Shannon information gain and the RMS water vapor error of the hyperspectral microwave radiometer. At an altitude of 1.5-6 km, more information can be obtained by increasing the number of microwave spectrum channels. For water vapor profiling, the improvement of the retrieval RMS error from 10 to 800 channels at a higher altitude exceeds about 5%-10%.

About this research paper

What this paper is about

In this letter, we study the performance of a K-band ground-based hyperspectral microwave radiometer for the observation of atmospheric water vapor. First, a prototype of a K-band ground-based hyperspectral microwave radiometer for atmospheric sounding is proposed. This microwave radiometer is able to split the 18-26-GHz signal into 80 hyperspectral channels with identical bandwidth. Simulation studies, including the retrieval performance of water vapor and the vertical resolution of observation compared with the five-humidity-channel radiometer TP/WVP-3000 under the same conditions, are presented to assess the capability of the prototype. Simulation results show that the vertical resolution of this prototype is better than that of TP/WVP-3000 at a higher altitude, and the RMS water vapor error improves by about 10% at an altitude of 0-6 km. Moreover, by simulation, we analyze the impact of the radiometer channel number on the Shannon information gain and the RMS water vapor error of the hyperspectral microwave radiometer. At an altitude of 1.5-6 km, more information can be obtained by increasing the number of microwave spectrum channels. For water vapor profiling, the improvement of the retrieval RMS error from 10 to 800 channels at a higher altitude exceeds about 5%-10%.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this letter, we study the performance of a K-band ground-based hyperspectral microwave radiometer for the observation of atmospheric water vapor. First, a prototype of a K-band ground-based hyperspectral microwave radiometer for atmospheric sounding is proposed. This microwave radiometer is able to split the 18-26-GHz signal into 80 hyperspectral channels with identical bandwidth. Simulation studies, including the retrieval performance of water vapor and the vertical resolution of observation compared with the five-humidity-channel radiometer TP/WVP-3000 under the same conditions, are presented to assess the capability of the prototype. Simulation results show that the vertical resolution of this prototype is better than that of TP/WVP-3000 at a higher altitude, and the RMS water vapor error improves by about 10% at an altitude of 0-6 km. Moreover, by simulation, we analyze the impact of the radiometer channel number on the Shannon information gain and the RMS water vapor error of the hyperspectral microwave radiometer. At an altitude of 1.5-6 km, more information can be obtained by increasing the number of microwave spectrum channels. For water vapor profiling, the improvement of the retrieval RMS error from 10 to 800 channels at a higher altitude exceeds about 5%-10%.

Key concepts: Remote sensing, Radiometer, Microwave radiometer, Environmental science, Depth sounding, Water vapor, Hyperspectral imaging, Microwave

Related papers

Back to paper searchBrowse research topicsOriginal source
Retrieval Analysis of Atmospheric Water Vapor for K-Band Ground-Based Hyperspectral Microwave Radiometer — Research Paper | ScholarLens