2009•Food Additives & Contaminants Part AOpen access

Validation of a liquid chromatography–mass spectrometry method for determining the migration of primary aromatic amines from cooking utensils and its application to actual samples

Raquel Sendón, Juana Bustos, Jose Juan Sánchez, Perfecto Paseiro, Ma Eugenia Cirugeda

Open full text 35 citations

Abstract

Many cooking utensils are made of nylon, a material that may incorporate azodyes and where primary aromatic amines (PAAs) are the starting substances. Moreover, aromatic amines may also be present as technical impurities. Another source of PAAs could be aromatic isocyanates used as monomers in the production of polyurethanes. The aim of this work was to validate a simple LC-MS/MS method for the determination of eight primary aromatic amines (m-phenylenediamine, 2,6- and 2,4-toluenediamine, 1,5-diaminonaphthalene, aniline, 4,4'-diaminonaphenylether, 4,4'-methylenedianiline and 3,3'-dimethylbenzidine) in the aqueous food simulant 3% acetic acid (w/v). The detection limits calculated were adequate with respect to present legislation. The method was validated at four concentration levels (2, 5 10 and 20 microg kg(-1)). Global internal reproducibility was in the range 5.6-21.4% (RSD(R)) depending on the compound and concentration. Mean recoveries for all levels varied between 89 and 100%, depending on the amine. A total of 39 samples of cooking utensils were analyzed using the described method and the results obtained after the third migration test were not compliant in approximately half of the samples.

About this research paper

What this paper is about

Many cooking utensils are made of nylon, a material that may incorporate azodyes and where primary aromatic amines (PAAs) are the starting substances. Moreover, aromatic amines may also be present as technical impurities. Another source of PAAs could be aromatic isocyanates used as monomers in the production of polyurethanes. The aim of this work was to validate a simple LC-MS/MS method for the determination of eight primary aromatic amines (m-phenylenediamine, 2,6- and 2,4-toluenediamine, 1,5-diaminonaphthalene, aniline, 4,4'-diaminonaphenylether, 4,4'-methylenedianiline and 3,3'-dimethylbenzidine) in the aqueous food simulant 3% acetic acid (w/v). The detection limits calculated were adequate with respect to present legislation. The method was validated at four concentration levels (2, 5 10 and 20 microg kg(-1)). Global internal reproducibility was in the range 5.6-21.4% (RSD(R)) depending on the compound and concentration. Mean recoveries for all levels varied between 89 and 100%, depending on the amine. A total of 39 samples of cooking utensils were analyzed using the described method and the results obtained after the third migration test were not compliant in approximately half of the samples.

Why it matters

OpenAlex reports 35 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Many cooking utensils are made of nylon, a material that may incorporate azodyes and where primary aromatic amines (PAAs) are the starting substances. Moreover, aromatic amines may also be present as technical impurities. Another source of PAAs could be aromatic isocyanates used as monomers in the production of polyurethanes. The aim of this work was to validate a simple LC-MS/MS method for the determination of eight primary aromatic amines (m-phenylenediamine, 2,6- and 2,4-toluenediamine, 1,5-diaminonaphthalene, aniline, 4,4'-diaminonaphenylether, 4,4'-methylenedianiline and 3,3'-dimethylbenzidine) in the aqueous food simulant 3% acetic acid (w/v). The detection limits calculated were adequate with respect to present legislation. The method was validated at four concentration levels (2, 5 10 and 20 microg kg(-1)). Global internal reproducibility was in the range 5.6-21.4% (RSD(R)) depending on the compound and concentration. Mean recoveries for all levels varied between 89 and 100%, depending on the amine. A total of 39 samples of cooking utensils were analyzed using the described method and the results obtained after the third migration test were not compliant in approximately half of the samples.

Key concepts: Aromatic amine, Chemistry, Aniline, Primary (astronomy), Chromatography, Acetic acid, Amine gas treating, Aniline Compounds

Related papers

Back to paper searchBrowse research topicsOriginal source
Validation of a liquid chromatography–mass spectrometry method for determining the migration of primary aromatic amines from cooking utensils and its application to actual samples — Research Paper | ScholarLens