2012•Unpublished venueRequires access

Impact of mains connected three-phase induction motor loading levels on network voltage unbalance attenuation

Upuli Jayatunga, Sarath Perera, Phil Ciufo

Open publisher page 10 citations

Abstract

Voltage unbalance (VU) in power systems should be managed in a systematic manner in order to minimise its adverse effects on both customer equipment and supply utilities. It is a well known fact that three-phase induction motor performance can be significantly affected in the presence of supply voltage unbalance. It is also known that three-phase induction motors can help to reduce pre-existing network voltage unbalance levels. Recently undertaken research aligned with IEC/TR 61000-3-13:2008 Technical Report on voltage unbalance management (emission allocation and emission assessment) have quantified the contribution made by induction motors to the net voltage unbalance at a point of connection. It is perceived that loading level of three-phase induction motors will have an influence on this contribution. Hence, this study focuses on a sensitivity analysis of induction motor loading level on the voltage unbalance emission contribution to the point of connection. Simulation work undertaken indicates that increased loading levels on induction motors tend to exacerbate negative sequence voltage unbalance factor (VUF) at the point of connection in comparison to lightly loaded induction motors.

About this research paper

What this paper is about

Voltage unbalance (VU) in power systems should be managed in a systematic manner in order to minimise its adverse effects on both customer equipment and supply utilities. It is a well known fact that three-phase induction motor performance can be significantly affected in the presence of supply voltage unbalance. It is also known that three-phase induction motors can help to reduce pre-existing network voltage unbalance levels. Recently undertaken research aligned with IEC/TR 61000-3-13:2008 Technical Report on voltage unbalance management (emission allocation and emission assessment) have quantified the contribution made by induction motors to the net voltage unbalance at a point of connection. It is perceived that loading level of three-phase induction motors will have an influence on this contribution. Hence, this study focuses on a sensitivity analysis of induction motor loading level on the voltage unbalance emission contribution to the point of connection. Simulation work undertaken indicates that increased loading levels on induction motors tend to exacerbate negative sequence voltage unbalance factor (VUF) at the point of connection in comparison to lightly loaded induction motors.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Voltage unbalance (VU) in power systems should be managed in a systematic manner in order to minimise its adverse effects on both customer equipment and supply utilities. It is a well known fact that three-phase induction motor performance can be significantly affected in the presence of supply voltage unbalance. It is also known that three-phase induction motors can help to reduce pre-existing network voltage unbalance levels. Recently undertaken research aligned with IEC/TR 61000-3-13:2008 Technical Report on voltage unbalance management (emission allocation and emission assessment) have quantified the contribution made by induction motors to the net voltage unbalance at a point of connection. It is perceived that loading level of three-phase induction motors will have an influence on this contribution. Hence, this study focuses on a sensitivity analysis of induction motor loading level on the voltage unbalance emission contribution to the point of connection. Simulation work undertaken indicates that increased loading levels on induction motors tend to exacerbate negative sequence voltage unbalance factor (VUF) at the point of connection in comparison to lightly loaded induction motors.

Key concepts: Induction motor, Voltage, Engineering, Sensitivity (control systems), Induction generator, Three-phase, Control theory (sociology), Electrical engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Impact of mains connected three-phase induction motor loading levels on network voltage unbalance attenuation — Research Paper | ScholarLens