Ultrasound-enhanced flow injection chemiluminescence for determination of hydrogen peroxide
Gillian M. Greenway, Tapparath Leelasattarathkul, Saisunee Liawruangrath, R. Alan Wheatley, Napaporn Youngvises
Abstract
Gillian M. Greenway, Tapparath Leelasattarathkul, Saisunee Liawruangrath, R. Alan Wheatley, Napaporn Youngvises
Abstract
A novel ultrasonic flow injection chemiluminescence (FI-CL) manifold for determining hydrogen peroxide (H2O2) has been designed and evaluated. Chemiluminescence obtained from the luminol-H2O2-cobalt(II) reaction was enhanced by applying 120 W of ultrasound for a period of 4 s to the reaction coil in the FI-CL system and this enhancement was verified by comparison with an identical manifold without ultrasound. The system was developed for determining ultra-trace levels of H2O2 and a calibration curve was obtained with a linear portion over the range of 10-200 nmol L(-1) H2O2 (correlation coefficient 0.9945). The detection limit (3sigma) and the quantification limit (LOQ) were found to be 1 x 10(-9) and 3.3 x 10(-9) mol L(-1) respectively and the relative standard deviation was 1.37% for 2 x 10(-7) mol L(-1) H2O2 (n = 10). The method was applied to the determination of trace amounts of H2O2 in purified water and natural water samples without any special pre-treatments.
OpenAlex reports 46 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A novel ultrasonic flow injection chemiluminescence (FI-CL) manifold for determining hydrogen peroxide (H2O2) has been designed and evaluated. Chemiluminescence obtained from the luminol-H2O2-cobalt(II) reaction was enhanced by applying 120 W of ultrasound for a period of 4 s to the reaction coil in the FI-CL system and this enhancement was verified by comparison with an identical manifold without ultrasound. The system was developed for determining ultra-trace levels of H2O2 and a calibration curve was obtained with a linear portion over the range of 10-200 nmol L(-1) H2O2 (correlation coefficient 0.9945). The detection limit (3sigma) and the quantification limit (LOQ) were found to be 1 x 10(-9) and 3.3 x 10(-9) mol L(-1) respectively and the relative standard deviation was 1.37% for 2 x 10(-7) mol L(-1) H2O2 (n = 10). The method was applied to the determination of trace amounts of H2O2 in purified water and natural water samples without any special pre-treatments.
Key concepts: Chemiluminescence, Detection limit, Luminol, Hydrogen peroxide, Calibration curve, Chemistry, Analytical Chemistry (journal), Relative standard deviation