2006•Journal of Advanced ScienceOpen access

Basic study of spatial resolution measurement for autoradiography systems

Hiroyuki Kudo, Elito Kazawa, Toru Sasaki, Akinori Iwamoto

Open full text 1 citations

Abstract

A spatial resolution of real-time bioradiography system was closely measured using PDMS (polydimethyl siloxane) microfluidic chips with microchannels down to 20um wide. We measured the spatial resolution by comparing line width of a chemiluminescence image and a beta-ray image. Both images were obtained using identical microchannel. Using our method, a spatial resolution can be measured within an equal condition to actual observation. In addition, the spatial resolution was improved upto 20um FWHM(Full Width at Half Maximum), which is 50 times better than that of conventional method. Owing this method, we experimentally confirmed that b-ray scattering degrades the spatial resolution of the β-ray image.

Open-access reader

About this research paper

What this paper is about

A spatial resolution of real-time bioradiography system was closely measured using PDMS (polydimethyl siloxane) microfluidic chips with microchannels down to 20um wide. We measured the spatial resolution by comparing line width of a chemiluminescence image and a beta-ray image. Both images were obtained using identical microchannel. Using our method, a spatial resolution can be measured within an equal condition to actual observation. In addition, the spatial resolution was improved upto 20um FWHM(Full Width at Half Maximum), which is 50 times better than that of conventional method. Owing this method, we experimentally confirmed that b-ray scattering degrades the spatial resolution of the β-ray image.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A spatial resolution of real-time bioradiography system was closely measured using PDMS (polydimethyl siloxane) microfluidic chips with microchannels down to 20um wide. We measured the spatial resolution by comparing line width of a chemiluminescence image and a beta-ray image. Both images were obtained using identical microchannel. Using our method, a spatial resolution can be measured within an equal condition to actual observation. In addition, the spatial resolution was improved upto 20um FWHM(Full Width at Half Maximum), which is 50 times better than that of conventional method. Owing this method, we experimentally confirmed that b-ray scattering degrades the spatial resolution of the β-ray image.

Key concepts: Image resolution, Full width at half maximum, Resolution (logic), Optics, Materials science, Microchannel, Microchannel plate detector, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Basic study of spatial resolution measurement for autoradiography systems — Research Paper | ScholarLens