1993Analytical LettersRequires access

Sensitive Synchronous Spectrofluorimetric Methods for the Determination of 1- and 2-Naphthol in Micellar Media

Ana Maria Afonso Perera, J. H. Ayala Díaz, A. González Armas, V. González Díaz

Open publisher page 5 citations

Abstract

The interaction of 1-naphthol and 2-naphthol with several quaternary ammonium salts was studied. Spectrofluorimetric methods were developed for the determination of both naphthols in hexadecyltrimethylammonium bromide micellar medium. The detection limits are 1.4 and 10.2 ng/ml for 1-naphthol, and 6.2 and 5.1 ng/ml for 2-naphthol employing the conventional and synchronous spectrofluorimetric methods, respectively. The use of the first-derivative spectrum allows for the simultaneous determination of both naphthols. The recoveries of 1-naphthol and 2-naphthol in natural waters are acceptable.

About this research paper

What this paper is about

The interaction of 1-naphthol and 2-naphthol with several quaternary ammonium salts was studied. Spectrofluorimetric methods were developed for the determination of both naphthols in hexadecyltrimethylammonium bromide micellar medium. The detection limits are 1.4 and 10.2 ng/ml for 1-naphthol, and 6.2 and 5.1 ng/ml for 2-naphthol employing the conventional and synchronous spectrofluorimetric methods, respectively. The use of the first-derivative spectrum allows for the simultaneous determination of both naphthols. The recoveries of 1-naphthol and 2-naphthol in natural waters are acceptable.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The interaction of 1-naphthol and 2-naphthol with several quaternary ammonium salts was studied. Spectrofluorimetric methods were developed for the determination of both naphthols in hexadecyltrimethylammonium bromide micellar medium. The detection limits are 1.4 and 10.2 ng/ml for 1-naphthol, and 6.2 and 5.1 ng/ml for 2-naphthol employing the conventional and synchronous spectrofluorimetric methods, respectively. The use of the first-derivative spectrum allows for the simultaneous determination of both naphthols. The recoveries of 1-naphthol and 2-naphthol in natural waters are acceptable.

Key concepts: Chemistry, 1-Naphthol, 2-Naphthol, Chromatography, Bromide, Ammonium bromide, Ammonium, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Sensitive Synchronous Spectrofluorimetric Methods for the Determination of 1- and 2-Naphthol in Micellar Media — Research Paper | ScholarLens