1983Journal of Applied CrystallographyRequires access

A novel curved position-sensitive proportional counter for X-ray diffractometry

Erich R. Wölfel

Open publisher page 59 citations

Abstract

A novel position-sensitive detector (PSD) is described which has been used on the STOE focusing monochromatic beam diffractometer. The anode wire of the PSD coincides with the focusing circle of the diffractometer and covers a range of Δ2θ = 60°. Within a few minutes, data were collected from polycrystalline transmission samples and capillaries, and with a furnace as an attachment to the diffractometer phase transitions and solid-state reactions were studied. Some of the results are discussed in this paper, the characteristics of the PSD are described and compared with conventional counters.

About this research paper

What this paper is about

A novel position-sensitive detector (PSD) is described which has been used on the STOE focusing monochromatic beam diffractometer. The anode wire of the PSD coincides with the focusing circle of the diffractometer and covers a range of Δ2θ = 60°. Within a few minutes, data were collected from polycrystalline transmission samples and capillaries, and with a furnace as an attachment to the diffractometer phase transitions and solid-state reactions were studied. Some of the results are discussed in this paper, the characteristics of the PSD are described and compared with conventional counters.

Why it matters

OpenAlex reports 59 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A novel position-sensitive detector (PSD) is described which has been used on the STOE focusing monochromatic beam diffractometer. The anode wire of the PSD coincides with the focusing circle of the diffractometer and covers a range of Δ2θ = 60°. Within a few minutes, data were collected from polycrystalline transmission samples and capillaries, and with a furnace as an attachment to the diffractometer phase transitions and solid-state reactions were studied. Some of the results are discussed in this paper, the characteristics of the PSD are described and compared with conventional counters.

Key concepts: Diffractometer, Monochromatic color, Proportional counter, Crystallite, Optics, Materials science, Detector, Range (aeronautics)

Related papers

Back to paper searchBrowse research topicsOriginal source
A novel curved position-sensitive proportional counter for X-ray diffractometry — Research Paper | ScholarLens