Quality assessment of platelet concentrates prepared by platelet rich plasma-platelet concentrate, buffy coat poor-platelet concentrate (BC-PC) and apheresis-PC methods
Ravindra Pratap Singh, Neelam Marwaha, Pankaj Malhotra, Sumitra Dash
Abstract
Ravindra Pratap Singh, Neelam Marwaha, Pankaj Malhotra, Sumitra Dash
Abstract
BACKGROUND: Platelet rich plasma-platelet concentrate (PRP-PC), buffy coat poor-platelet concentrate (BC-PC), and apheresis-PC were prepared and their quality parameters were assessed. STUDY DESIGN: IN THIS STUDY, THE FOLLOWING PLATELET PRODUCTS WERE PREPARED: from random donor platelets (i) platelet rich plasma - platelet concentrate (PRP-PC), and (ii) buffy coat poor-platelet concentrate (BC-PC) and (iii) single donor platelets (apheresis-PC) by different methods. Their quality was assessed using the following parameters: swirling, volume of the platelet concentrate, platelet count, WBC count and pH. RESULTS: A total of 146 platelet concentrates (64 of PRP-PC, 62 of BC-PC and 20 of apheresis-PC) were enrolled in this study. The mean volume of PRP-PC, BC-PC and apheresis-PC was 62.30+/-22.68 ml, 68.81+/-22.95 ml and 214.05+/-9.91 ml and ranged from 22-135 ml, 32-133 ml and 200-251 ml respectively. The mean platelet count of PRP-PC, BC-PC and apheresis-PC was 7.6+/-2.97 x 1010/unit, 7.3+/-2.98 x 1010/unit and 4.13+/-1.32 x 1011/unit and ranged from 3.2 -16.2 x 1010/unit, 0.6-16.4 x 1010/unit and 1.22-8.9 x 1011/unit respectively. The mean WBC count in PRP-PC (n = 10), BC-PC (n = 10) and apheresis-PC (n = 6) units was 4.05+/-0.48 x 107/unit, 2.08+/-0.39 x 107/unit and 4.8+/-0.8 x 106/unit and ranged from 3.4 -4.77 x 107/unit, 1.6-2.7 x 107/unit and 3.2 - 5.2 x 106/unit respectively. A total of 26 units were analyzed for pH changes. Out of these units, 10 each were PRP-PC and BC-PC and 6 units were apheresis-PC. Their mean pH was 6.7+/-0.26 (mean+/-SD) and ranged from 6.5 - 7.0 and no difference was observed among all three types of platelet concentrate. CONCLUSION: PRP-PC and BC-PC units were comparable in terms of swirling, platelet count per unit and pH. As expected, we found WBC contamination to be less in BC-PC than PRP-PC units. Variation in volume was more in BC-PC than PRP-PC units and this suggests that further standardization is required for preparation of BC-PC. As compared to the above two platelet concentrates, all the units of apheresis-PC fulfilled the desired quality control criteria of volume. Apheresis-PC units showed better swirling and platelet count than PRP-PCs and BC-PCs. All the platelet concentrates units had pH well above the recommended norm.
OpenAlex reports 87 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
BACKGROUND: Platelet rich plasma-platelet concentrate (PRP-PC), buffy coat poor-platelet concentrate (BC-PC), and apheresis-PC were prepared and their quality parameters were assessed. STUDY DESIGN: IN THIS STUDY, THE FOLLOWING PLATELET PRODUCTS WERE PREPARED: from random donor platelets (i) platelet rich plasma - platelet concentrate (PRP-PC), and (ii) buffy coat poor-platelet concentrate (BC-PC) and (iii) single donor platelets (apheresis-PC) by different methods. Their quality was assessed using the following parameters: swirling, volume of the platelet concentrate, platelet count, WBC count and pH. RESULTS: A total of 146 platelet concentrates (64 of PRP-PC, 62 of BC-PC and 20 of apheresis-PC) were enrolled in this study. The mean volume of PRP-PC, BC-PC and apheresis-PC was 62.30+/-22.68 ml, 68.81+/-22.95 ml and 214.05+/-9.91 ml and ranged from 22-135 ml, 32-133 ml and 200-251 ml respectively. The mean platelet count of PRP-PC, BC-PC and apheresis-PC was 7.6+/-2.97 x 1010/unit, 7.3+/-2.98 x 1010/unit and 4.13+/-1.32 x 1011/unit and ranged from 3.2 -16.2 x 1010/unit, 0.6-16.4 x 1010/unit and 1.22-8.9 x 1011/unit respectively. The mean WBC count in PRP-PC (n = 10), BC-PC (n = 10) and apheresis-PC (n = 6) units was 4.05+/-0.48 x 107/unit, 2.08+/-0.39 x 107/unit and 4.8+/-0.8 x 106/unit and ranged from 3.4 -4.77 x 107/unit, 1.6-2.7 x 107/unit and 3.2 - 5.2 x 106/unit respectively. A total of 26 units were analyzed for pH changes. Out of these units, 10 each were PRP-PC and BC-PC and 6 units were apheresis-PC. Their mean pH was 6.7+/-0.26 (mean+/-SD) and ranged from 6.5 - 7.0 and no difference was observed among all three types of platelet concentrate. CONCLUSION: PRP-PC and BC-PC units were comparable in terms of swirling, platelet count per unit and pH. As expected, we found WBC contamination to be less in BC-PC than PRP-PC units. Variation in volume was more in BC-PC than PRP-PC units and this suggests that further standardization is required for preparation of BC-PC. As compared to the above two platelet concentrates, all the units of apheresis-PC fulfilled the desired quality control criteria of volume. Apheresis-PC units showed better swirling and platelet count than PRP-PCs and BC-PCs. All the platelet concentrates units had pH well above the recommended norm.
Key concepts: Buffy coat, Platelet, Apheresis, Platelet concentrate, Medicine, Plateletpheresis, Mean platelet volume, Internal medicine