2006Journal of Geotechnical and Geoenvironmental EngineeringRequires access

Bearing Capacity of Square and Circular Footings on a Finite Layer of Granular Soil Underlain by a Rigid Base

Amy B. Cerato, Alan J. Lutenegger

Open publisher page 94 citations

Abstract

Traditional bearing capacity theories for the ultimate capacity of shallow foundations assume that the thickness of the bearing stratum is infinite. The presence of a hard layer within a certain depth below the foundation can significantly influence the unit load supported by the soil. Therefore the original bearing capacity equations should be modified to account for this condition in determining the ultimate bearing capacity. In order to evaluate this phenomenon further, model square and circular footing tests were performed on a bed of well-graded sand. Test beds were prepared at three different relative densities corresponding to loose, medium, and dense conditions: Dr=24, 57, and 87%, using five different sand layer thicknesses, H; H∕B values of 0.5, 1, 2, 3, and 4, where B is the footing width. Results of the model scale footing tests show that the bearing capacity factor, Nγ, should be modified up to H∕B=3, instead of H∕B=1, as previously suggested. The footing shape factor, sγ, should account for both shape and finite layering. This technical note gives a description of the test methods and material used and presents the test results in comparison to previous results.

About this research paper

What this paper is about

Traditional bearing capacity theories for the ultimate capacity of shallow foundations assume that the thickness of the bearing stratum is infinite. The presence of a hard layer within a certain depth below the foundation can significantly influence the unit load supported by the soil. Therefore the original bearing capacity equations should be modified to account for this condition in determining the ultimate bearing capacity. In order to evaluate this phenomenon further, model square and circular footing tests were performed on a bed of well-graded sand. Test beds were prepared at three different relative densities corresponding to loose, medium, and dense conditions: Dr=24, 57, and 87%, using five different sand layer thicknesses, H; H∕B values of 0.5, 1, 2, 3, and 4, where B is the footing width. Results of the model scale footing tests show that the bearing capacity factor, Nγ, should be modified up to H∕B=3, instead of H∕B=1, as previously suggested. The footing shape factor, sγ, should account for both shape and finite layering. This technical note gives a description of the test methods and material used and presents the test results in comparison to previous results.

Why it matters

OpenAlex reports 94 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Traditional bearing capacity theories for the ultimate capacity of shallow foundations assume that the thickness of the bearing stratum is infinite. The presence of a hard layer within a certain depth below the foundation can significantly influence the unit load supported by the soil. Therefore the original bearing capacity equations should be modified to account for this condition in determining the ultimate bearing capacity. In order to evaluate this phenomenon further, model square and circular footing tests were performed on a bed of well-graded sand. Test beds were prepared at three different relative densities corresponding to loose, medium, and dense conditions: Dr=24, 57, and 87%, using five different sand layer thicknesses, H; H∕B values of 0.5, 1, 2, 3, and 4, where B is the footing width. Results of the model scale footing tests show that the bearing capacity factor, Nγ, should be modified up to H∕B=3, instead of H∕B=1, as previously suggested. The footing shape factor, sγ, should account for both shape and finite layering. This technical note gives a description of the test methods and material used and presents the test results in comparison to previous results.

Key concepts: Bearing capacity, Geotechnical engineering, Square (algebra), Foundation (evidence), Bearing (navigation), Shallow foundation, Layering, Structural engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Bearing Capacity of Square and Circular Footings on a Finite Layer of Granular Soil Underlain by a Rigid Base — Research Paper | ScholarLens