2013•Chemistry LettersRequires access

Application of Graphene as a Sorbent for Preconcentration and Determination of Trace Amounts of Cadmium

Yunkun Wang, Yanli Dong, Jingwen Zhang, Chao Li, Jingci Li, Jing‐Jun Ma

Open publisher page 3 citations

Abstract

Abstract A new method using a column packed with graphene as sorbent was developed for the preconcentration of trace amounts of cadmium (Cd) prior to its determination by flame atomic absorption spectrometry. Under the optimal conditions, the calibration graph was linear in the concentration range of 10.0–150.0 µg L−1 with a detection limit of 0.60 µg L−1. The relative standard deviation for ten replicate measurements of 100.0 µg L−1 of Cd was 3.25%.

About this research paper

What this paper is about

Abstract A new method using a column packed with graphene as sorbent was developed for the preconcentration of trace amounts of cadmium (Cd) prior to its determination by flame atomic absorption spectrometry. Under the optimal conditions, the calibration graph was linear in the concentration range of 10.0–150.0 µg L−1 with a detection limit of 0.60 µg L−1. The relative standard deviation for ten replicate measurements of 100.0 µg L−1 of Cd was 3.25%.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract A new method using a column packed with graphene as sorbent was developed for the preconcentration of trace amounts of cadmium (Cd) prior to its determination by flame atomic absorption spectrometry. Under the optimal conditions, the calibration graph was linear in the concentration range of 10.0–150.0 µg L−1 with a detection limit of 0.60 µg L−1. The relative standard deviation for ten replicate measurements of 100.0 µg L−1 of Cd was 3.25%.

Key concepts: Sorbent, Chemistry, Cadmium, Detection limit, Relative standard deviation, Calibration curve, Trace Amounts, Atomic absorption spectroscopy

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of Graphene as a Sorbent for Preconcentration and Determination of Trace Amounts of Cadmium — Research Paper | ScholarLens