OPTIMUM CONDITIONS FOR THE REPRODUCIBLE MEASUREMENT OF CONCANAVALIN A-ACTIVATED SUPPRESSOR CELL ACTIVITY

Timothy L. Ratliff, Robert E. McCool, William J. Catàlona

Open publisher page 4 citations

Abstract

The reproducibility of the measurement of concanavalin A (Con A)-inducible suppressor cell activity in human peripheral blood lymphocytes was examined. Suppressor cells were activated for 24, 48, or 72 hr with 3, 6, and 12 micrograms of Con A (Con A in concentrations greater than 12 micrograms/ml was toxic to the lymphocytes) per ml and suppression of the proliferative response of autologous lymphocytes to varying concentrations of Con A (3, 6, and 12 micrograms/ml) was measured. No single set of conditions consistently produced optimal suppression. Assays performed concurrently using lymphocytes from the same subject produced comparable suppressor cell activity; however, considerable variability in suppressor cell activity was observed under all conditions tested when five normal subjects were examined on as many as four separate occasions. The variability was reduced but not eliminated by reporting the data for each assay in terms of a peak suppression value determined from multiple sets of conditions. The results suggest that small differences in suppressor cell activity between patient groups may be masked by the intrinsic variability of the assay system.

About this research paper

What this paper is about

The reproducibility of the measurement of concanavalin A (Con A)-inducible suppressor cell activity in human peripheral blood lymphocytes was examined. Suppressor cells were activated for 24, 48, or 72 hr with 3, 6, and 12 micrograms of Con A (Con A in concentrations greater than 12 micrograms/ml was toxic to the lymphocytes) per ml and suppression of the proliferative response of autologous lymphocytes to varying concentrations of Con A (3, 6, and 12 micrograms/ml) was measured. No single set of conditions consistently produced optimal suppression. Assays performed concurrently using lymphocytes from the same subject produced comparable suppressor cell activity; however, considerable variability in suppressor cell activity was observed under all conditions tested when five normal subjects were examined on as many as four separate occasions. The variability was reduced but not eliminated by reporting the data for each assay in terms of a peak suppression value determined from multiple sets of conditions. The results suggest that small differences in suppressor cell activity between patient groups may be masked by the intrinsic variability of the assay system.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The reproducibility of the measurement of concanavalin A (Con A)-inducible suppressor cell activity in human peripheral blood lymphocytes was examined. Suppressor cells were activated for 24, 48, or 72 hr with 3, 6, and 12 micrograms of Con A (Con A in concentrations greater than 12 micrograms/ml was toxic to the lymphocytes) per ml and suppression of the proliferative response of autologous lymphocytes to varying concentrations of Con A (3, 6, and 12 micrograms/ml) was measured. No single set of conditions consistently produced optimal suppression. Assays performed concurrently using lymphocytes from the same subject produced comparable suppressor cell activity; however, considerable variability in suppressor cell activity was observed under all conditions tested when five normal subjects were examined on as many as four separate occasions. The variability was reduced but not eliminated by reporting the data for each assay in terms of a peak suppression value determined from multiple sets of conditions. The results suggest that small differences in suppressor cell activity between patient groups may be masked by the intrinsic variability of the assay system.

Key concepts: Concanavalin A, Suppressor, Cell, Peripheral blood, Reproducibility, Immunology, Chemistry, Biology