2008World Journal of SurgeryRequires access

Effects of Posture and Prolonged Pneumoperitoneum on Hemodynamic Parameters during Laparoscopy

Dirk Meininger, K. Westphal, Dorothee H. Bremerich, Heiner Runkel, Michael Probst, Bernhard Zwißler, Christian Byhahn

Open publisher page 79 citations

Abstract

BACKGROUND: The present prospective study was designed to evaluate hemodynamic changes associated with head-down positioning and prolonged pneumoperitoneum during totally endoscopic robot-assisted radical prostatectomy. METHODS: Ten American Society of Anesthesiologists (ASA) physical status I-III patients undergoing totally endoscopic robot-assisted radical prostatectomy were enrolled in the study. Invasive hemodynamic parameters were measured by transpulmonary arterial thermodilution using the PiCCO system with a femoral artery catheter. Cardiac index (CI), heart rate (HR), mean arterial pressure (MAP), systemic vascular resistance index (SVRI), intrathoracic blood volume (ITBV), and central venous pressure (CVP) were recorded with the patient in the supine position, after head-down tilt, intraoperatively after 30 min, 1 h, 2 h, 3 h, and 4 h of pneumoperitoneum at an insufflation pressure of 12 mmHg, after deflation still with head-down positioning, and finally, with the patient in the supine position. RESULTS: Placing the patient in the Trendelenburg (head-down) position caused a significant increase in CVP (from 9.9 +/- 3.4 to 15.1 +/- 2.3 mmHg), whereas all other hemodynamic parameters remained nearly unaffected. The induction of pneumoperitoneum resulted in a significant increase in MAP (from 74.9 +/- 12.9 to 95.4 +/- 11.9 mmHg). No other parameter was affected. Even at 4 h of pneumoperitoneum only mild hemodynamic changes were observed. After release of the pneumoperitoneum with the patient still in the head-down position, HR (49.0 +/- 4 versus 63.9 +/- 12.4 min(-1)) and after placing the patient in the supine position, CI (2.4 +/- 0.2 versus 3.3 +/- 0.7 l min(-1 )m(-2)) increased significantly, whereas CVP returned to baseline values. CONCLUSIONS: Patients undergoing totally endoscopic radical prostatectomy with 4 h of pneumoperitoneum in the Trendelenburg position experienced no significant hemodynamic depression during posture and pneumoperitoneum.

About this research paper

What this paper is about

BACKGROUND: The present prospective study was designed to evaluate hemodynamic changes associated with head-down positioning and prolonged pneumoperitoneum during totally endoscopic robot-assisted radical prostatectomy. METHODS: Ten American Society of Anesthesiologists (ASA) physical status I-III patients undergoing totally endoscopic robot-assisted radical prostatectomy were enrolled in the study. Invasive hemodynamic parameters were measured by transpulmonary arterial thermodilution using the PiCCO system with a femoral artery catheter. Cardiac index (CI), heart rate (HR), mean arterial pressure (MAP), systemic vascular resistance index (SVRI), intrathoracic blood volume (ITBV), and central venous pressure (CVP) were recorded with the patient in the supine position, after head-down tilt, intraoperatively after 30 min, 1 h, 2 h, 3 h, and 4 h of pneumoperitoneum at an insufflation pressure of 12 mmHg, after deflation still with head-down positioning, and finally, with the patient in the supine position. RESULTS: Placing the patient in the Trendelenburg (head-down) position caused a significant increase in CVP (from 9.9 +/- 3.4 to 15.1 +/- 2.3 mmHg), whereas all other hemodynamic parameters remained nearly unaffected. The induction of pneumoperitoneum resulted in a significant increase in MAP (from 74.9 +/- 12.9 to 95.4 +/- 11.9 mmHg). No other parameter was affected. Even at 4 h of pneumoperitoneum only mild hemodynamic changes were observed. After release of the pneumoperitoneum with the patient still in the head-down position, HR (49.0 +/- 4 versus 63.9 +/- 12.4 min(-1)) and after placing the patient in the supine position, CI (2.4 +/- 0.2 versus 3.3 +/- 0.7 l min(-1 )m(-2)) increased significantly, whereas CVP returned to baseline values. CONCLUSIONS: Patients undergoing totally endoscopic radical prostatectomy with 4 h of pneumoperitoneum in the Trendelenburg position experienced no significant hemodynamic depression during posture and pneumoperitoneum.

Why it matters

OpenAlex reports 79 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: The present prospective study was designed to evaluate hemodynamic changes associated with head-down positioning and prolonged pneumoperitoneum during totally endoscopic robot-assisted radical prostatectomy. METHODS: Ten American Society of Anesthesiologists (ASA) physical status I-III patients undergoing totally endoscopic robot-assisted radical prostatectomy were enrolled in the study. Invasive hemodynamic parameters were measured by transpulmonary arterial thermodilution using the PiCCO system with a femoral artery catheter. Cardiac index (CI), heart rate (HR), mean arterial pressure (MAP), systemic vascular resistance index (SVRI), intrathoracic blood volume (ITBV), and central venous pressure (CVP) were recorded with the patient in the supine position, after head-down tilt, intraoperatively after 30 min, 1 h, 2 h, 3 h, and 4 h of pneumoperitoneum at an insufflation pressure of 12 mmHg, after deflation still with head-down positioning, and finally, with the patient in the supine position. RESULTS: Placing the patient in the Trendelenburg (head-down) position caused a significant increase in CVP (from 9.9 +/- 3.4 to 15.1 +/- 2.3 mmHg), whereas all other hemodynamic parameters remained nearly unaffected. The induction of pneumoperitoneum resulted in a significant increase in MAP (from 74.9 +/- 12.9 to 95.4 +/- 11.9 mmHg). No other parameter was affected. Even at 4 h of pneumoperitoneum only mild hemodynamic changes were observed. After release of the pneumoperitoneum with the patient still in the head-down position, HR (49.0 +/- 4 versus 63.9 +/- 12.4 min(-1)) and after placing the patient in the supine position, CI (2.4 +/- 0.2 versus 3.3 +/- 0.7 l min(-1 )m(-2)) increased significantly, whereas CVP returned to baseline values. CONCLUSIONS: Patients undergoing totally endoscopic radical prostatectomy with 4 h of pneumoperitoneum in the Trendelenburg position experienced no significant hemodynamic depression during posture and pneumoperitoneum.

Key concepts: Pneumoperitoneum, Medicine, Trendelenburg position, Supine position, Hemodynamics, Anesthesia, Cardiac index, Central venous pressure

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of Posture and Prolonged Pneumoperitoneum on Hemodynamic Parameters during Laparoscopy — Research Paper | ScholarLens