2000Clinical ScienceRequires access

Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one-compartmental model

Roland Materne, Bernard E. Van Beers, Anne M. Smith, Isabelle Leconte, Jacques Jamart, Jean‐Paul Dehoux, André Keyeux, Yves Horsmans

Open publisher page 129 citations

Abstract

Various liver diseases lead to significant alterations of the hepatic microcirculation. Therefore, quantification of hepatic perfusion has the potential to improve the assessment and management of liver diseases. Most methods used to quantify liver perfusion are invasive or controversial. This paper describes and validates a non-invasive method for the quantification of liver perfusion using computed tomography (CT). Dynamic single-section CT of the liver was performed after intravenous bolus administration of a low-molecular-mass iodinated contrast agent. Hepatic, aortic and portal-venous time-density curves were fitted with a dual-input one-compartmental model to calculate liver perfusion. Validation studies consisted of simultaneous measurements of hepatic perfusion with CT and with radiolabelled microspheres in rabbits at rest and after adenosine infusion. The feasibility and reproducibility of the CT method in humans was assessed by three observers in 10 patients without liver disease. In rabbits, significant correlations were observed between perfusion measurements obtained with CT and with microspheres (r=0.92 for total liver perfusion, r=0.81 for arterial perfusion and r=0.85 for portal perfusion). In patients, total liver plasma perfusion measured with CT was 112+/-28 ml.min(-1).100 ml(-1), arterial plasma perfusion was 18+/-12 ml.min(-1).100 ml(-1) and portal plasma perfusion was 93+/-31 ml.min(-1).100 ml(-1). The measurements obtained by the three observers were not significantly different from each other (P>0.1). Our results indicate that dynamic CT combined with a dual-input one-compartmental model provides a valid and reliable method for the non-invasive quantification of perfusion in the normal liver.

About this research paper

What this paper is about

Various liver diseases lead to significant alterations of the hepatic microcirculation. Therefore, quantification of hepatic perfusion has the potential to improve the assessment and management of liver diseases. Most methods used to quantify liver perfusion are invasive or controversial. This paper describes and validates a non-invasive method for the quantification of liver perfusion using computed tomography (CT). Dynamic single-section CT of the liver was performed after intravenous bolus administration of a low-molecular-mass iodinated contrast agent. Hepatic, aortic and portal-venous time-density curves were fitted with a dual-input one-compartmental model to calculate liver perfusion. Validation studies consisted of simultaneous measurements of hepatic perfusion with CT and with radiolabelled microspheres in rabbits at rest and after adenosine infusion. The feasibility and reproducibility of the CT method in humans was assessed by three observers in 10 patients without liver disease. In rabbits, significant correlations were observed between perfusion measurements obtained with CT and with microspheres (r=0.92 for total liver perfusion, r=0.81 for arterial perfusion and r=0.85 for portal perfusion). In patients, total liver plasma perfusion measured with CT was 112+/-28 ml.min(-1).100 ml(-1), arterial plasma perfusion was 18+/-12 ml.min(-1).100 ml(-1) and portal plasma perfusion was 93+/-31 ml.min(-1).100 ml(-1). The measurements obtained by the three observers were not significantly different from each other (P>0.1). Our results indicate that dynamic CT combined with a dual-input one-compartmental model provides a valid and reliable method for the non-invasive quantification of perfusion in the normal liver.

Why it matters

OpenAlex reports 129 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Various liver diseases lead to significant alterations of the hepatic microcirculation. Therefore, quantification of hepatic perfusion has the potential to improve the assessment and management of liver diseases. Most methods used to quantify liver perfusion are invasive or controversial. This paper describes and validates a non-invasive method for the quantification of liver perfusion using computed tomography (CT). Dynamic single-section CT of the liver was performed after intravenous bolus administration of a low-molecular-mass iodinated contrast agent. Hepatic, aortic and portal-venous time-density curves were fitted with a dual-input one-compartmental model to calculate liver perfusion. Validation studies consisted of simultaneous measurements of hepatic perfusion with CT and with radiolabelled microspheres in rabbits at rest and after adenosine infusion. The feasibility and reproducibility of the CT method in humans was assessed by three observers in 10 patients without liver disease. In rabbits, significant correlations were observed between perfusion measurements obtained with CT and with microspheres (r=0.92 for total liver perfusion, r=0.81 for arterial perfusion and r=0.85 for portal perfusion). In patients, total liver plasma perfusion measured with CT was 112+/-28 ml.min(-1).100 ml(-1), arterial plasma perfusion was 18+/-12 ml.min(-1).100 ml(-1) and portal plasma perfusion was 93+/-31 ml.min(-1).100 ml(-1). The measurements obtained by the three observers were not significantly different from each other (P>0.1). Our results indicate that dynamic CT combined with a dual-input one-compartmental model provides a valid and reliable method for the non-invasive quantification of perfusion in the normal liver.

Key concepts: Perfusion, Liver perfusion, Medicine, Perfusion scanning, Nuclear medicine, Microcirculation, Arterial perfusion, Bolus (digestion)

Related papers

Back to paper searchBrowse research topicsOriginal source
Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one-compartmental model — Research Paper | ScholarLens