Changes of cardiac output during treadmill exercise by impedance cardiography
Soo Kwan Hwang, Deok Won Kim, Seong Kyeong Ko, Chang Kew Kim
Abstract
Soo Kwan Hwang, Deok Won Kim, Seong Kyeong Ko, Chang Kew Kim
Abstract
Nine athletes and ten nonathletes were selected randomly to study the changes of cardiac function during exercise by impedance cardiography. The speed of the treadmill was maintained at 3.4 mph, and its grade was increased by 1% (Balke protocol). The exercise was continued until the target heart rate (THR), 85% of maximum oxygen uptake (VO2max). The measured parameters for pre- and post-exercise were stroke volume (SV), heart rate (HR), and cardiac output (CO). Average stroke volume of athletes at pre-exercise, 71.1 ml, was higher than that of nonathletes, 64.6 ml, and stroke volume of the former at post-exercise, 97.0 ml, was also higher than that of the latter, 85.2 ml. Therefore, despite the lower heart rate, cardiac outputs of athletes at pre- and post-exercise, 4.98 and 16.3 L/min, were higher than those of nonathletes, 4.87 and 14.2 L/min. For the second phase of the study, cardiac outputs of three subjects were measured during the continuous treadmill exercise with newly developed electrodes and shoes for minimizing motion artifact. Though there were several studies measuring cardiac output during continuous bicycle exercise, this is thought to be the first study in the world measuring cardiac output during continuous treadmill exercise without aid of ensemble averaging.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Nine athletes and ten nonathletes were selected randomly to study the changes of cardiac function during exercise by impedance cardiography. The speed of the treadmill was maintained at 3.4 mph, and its grade was increased by 1% (Balke protocol). The exercise was continued until the target heart rate (THR), 85% of maximum oxygen uptake (VO2max). The measured parameters for pre- and post-exercise were stroke volume (SV), heart rate (HR), and cardiac output (CO). Average stroke volume of athletes at pre-exercise, 71.1 ml, was higher than that of nonathletes, 64.6 ml, and stroke volume of the former at post-exercise, 97.0 ml, was also higher than that of the latter, 85.2 ml. Therefore, despite the lower heart rate, cardiac outputs of athletes at pre- and post-exercise, 4.98 and 16.3 L/min, were higher than those of nonathletes, 4.87 and 14.2 L/min. For the second phase of the study, cardiac outputs of three subjects were measured during the continuous treadmill exercise with newly developed electrodes and shoes for minimizing motion artifact. Though there were several studies measuring cardiac output during continuous bicycle exercise, this is thought to be the first study in the world measuring cardiac output during continuous treadmill exercise without aid of ensemble averaging.
Key concepts: Impedance cardiography, Stroke volume, Cardiac output, Heart rate, Medicine, Treadmill, Cardiology, Cardiac function curve