2012Journal of Fire SciencesRequires access

Global modelling of fire protection performance of an intumescent coating under different furnace fire conditions

Yong Zhang, Yong Wang, Colin Bailey, Andrew Taylor

Open publisher page 62 citations

Abstract

This article presents a method to model the overall fire protection performance of an intumescent coating under different post-flashover furnace fire conditions. Intumescent coatings are reactive fire protection materials, and their fire protection performance, among which the maximum expansion ratio is the key indicator, depends on the heating condition. The aim of this research is to find one common set of properties to enable the intumescent coating fire protection performance to be predicted across different heating conditions on the intumescent coating. The obtained properties are implemented in a model to predict the global expansion process of intumescent coating and the protected steel substrate temperature under various furnace temperature–time curves. This model has previously been demonstrated by the authors to provide accurate results for cone calorimeter tests under different levels of radiant heat flux (50 and 65 kW m −2 ) and with different combinations of steel plate thickness (5, 10 and 20 mm) and intumescent coating dry film thickness (0.4, 0.8 and 1.2 mm). This article will present the experimental results of post-flashover furnace fire tests under different fire temperature–time relationships (slow, fast and standard) for the same combinations of steel plate thickness and dry film thickness as used in the cone calorimeter tests. A comparison between the prediction and experimental results indicates that the steel plate temperature results are typically within 10% and the final expanded thickness within 20% of each other.

About this research paper

What this paper is about

This article presents a method to model the overall fire protection performance of an intumescent coating under different post-flashover furnace fire conditions. Intumescent coatings are reactive fire protection materials, and their fire protection performance, among which the maximum expansion ratio is the key indicator, depends on the heating condition. The aim of this research is to find one common set of properties to enable the intumescent coating fire protection performance to be predicted across different heating conditions on the intumescent coating. The obtained properties are implemented in a model to predict the global expansion process of intumescent coating and the protected steel substrate temperature under various furnace temperature–time curves. This model has previously been demonstrated by the authors to provide accurate results for cone calorimeter tests under different levels of radiant heat flux (50 and 65 kW m −2 ) and with different combinations of steel plate thickness (5, 10 and 20 mm) and intumescent coating dry film thickness (0.4, 0.8 and 1.2 mm). This article will present the experimental results of post-flashover furnace fire tests under different fire temperature–time relationships (slow, fast and standard) for the same combinations of steel plate thickness and dry film thickness as used in the cone calorimeter tests. A comparison between the prediction and experimental results indicates that the steel plate temperature results are typically within 10% and the final expanded thickness within 20% of each other.

Why it matters

OpenAlex reports 62 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This article presents a method to model the overall fire protection performance of an intumescent coating under different post-flashover furnace fire conditions. Intumescent coatings are reactive fire protection materials, and their fire protection performance, among which the maximum expansion ratio is the key indicator, depends on the heating condition. The aim of this research is to find one common set of properties to enable the intumescent coating fire protection performance to be predicted across different heating conditions on the intumescent coating. The obtained properties are implemented in a model to predict the global expansion process of intumescent coating and the protected steel substrate temperature under various furnace temperature–time curves. This model has previously been demonstrated by the authors to provide accurate results for cone calorimeter tests under different levels of radiant heat flux (50 and 65 kW m −2 ) and with different combinations of steel plate thickness (5, 10 and 20 mm) and intumescent coating dry film thickness (0.4, 0.8 and 1.2 mm). This article will present the experimental results of post-flashover furnace fire tests under different fire temperature–time relationships (slow, fast and standard) for the same combinations of steel plate thickness and dry film thickness as used in the cone calorimeter tests. A comparison between the prediction and experimental results indicates that the steel plate temperature results are typically within 10% and the final expanded thickness within 20% of each other.

Key concepts: Intumescent, Cone calorimeter, Coating, Fire performance, Fire test, Materials science, Fire protection, Composite material

Related papers

Back to paper searchBrowse research topicsOriginal source
Global modelling of fire protection performance of an intumescent coating under different furnace fire conditions — Research Paper | ScholarLens