1995Skin Research and TechnologyRequires access

High‐frequency ultrasound measurement of dermis and subcutaneous fat in the newborn infant

Jes Reinholdt Petersen, Sten Petersen, Jørgen Serup

Open publisher page 15 citations

Abstract

BACKGROUND/AIMS: Skin thickness and subcutaneous fat thickness of newborn infants may reflect the condition of the infant including prematurity. Skin thickness and subcutaneous fat thickness might be useful parameters to characterize and monitor the nutritional state of the infant. The objective was to introduce ultrasonography for this purpose. METHODS: A high-frequency (20 MHz) ultrasound A-mode scanner was employed. Skinfold caliper recordings were performed for comparison. Frontal skin and skin of the back were studied in 7 infants with body weight 1095-4750 g (also studied with B-mode scanning). 46 infants weighing 925-4120 g were studied and correlated with skinfold recording. RESULTS: A high degree of correlation between skinfold recordings and ultrasound measurements (A-mode) of subcutaneous fat was found, coefficient of correlation 0.84, p<0.001. CONCLUSIONS: High-frequency ultrasound measurement of skin and subcutaneous fat thickness is precise and reliable for in vivo assessment of body fat in newborn infants. Further validation of the technique relative to neonatal skin and nutritional state is, however, needed before the ultrasound technique can be used as routine in neonatalogical monitoring.

About this research paper

What this paper is about

BACKGROUND/AIMS: Skin thickness and subcutaneous fat thickness of newborn infants may reflect the condition of the infant including prematurity. Skin thickness and subcutaneous fat thickness might be useful parameters to characterize and monitor the nutritional state of the infant. The objective was to introduce ultrasonography for this purpose. METHODS: A high-frequency (20 MHz) ultrasound A-mode scanner was employed. Skinfold caliper recordings were performed for comparison. Frontal skin and skin of the back were studied in 7 infants with body weight 1095-4750 g (also studied with B-mode scanning). 46 infants weighing 925-4120 g were studied and correlated with skinfold recording. RESULTS: A high degree of correlation between skinfold recordings and ultrasound measurements (A-mode) of subcutaneous fat was found, coefficient of correlation 0.84, p<0.001. CONCLUSIONS: High-frequency ultrasound measurement of skin and subcutaneous fat thickness is precise and reliable for in vivo assessment of body fat in newborn infants. Further validation of the technique relative to neonatal skin and nutritional state is, however, needed before the ultrasound technique can be used as routine in neonatalogical monitoring.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND/AIMS: Skin thickness and subcutaneous fat thickness of newborn infants may reflect the condition of the infant including prematurity. Skin thickness and subcutaneous fat thickness might be useful parameters to characterize and monitor the nutritional state of the infant. The objective was to introduce ultrasonography for this purpose. METHODS: A high-frequency (20 MHz) ultrasound A-mode scanner was employed. Skinfold caliper recordings were performed for comparison. Frontal skin and skin of the back were studied in 7 infants with body weight 1095-4750 g (also studied with B-mode scanning). 46 infants weighing 925-4120 g were studied and correlated with skinfold recording. RESULTS: A high degree of correlation between skinfold recordings and ultrasound measurements (A-mode) of subcutaneous fat was found, coefficient of correlation 0.84, p<0.001. CONCLUSIONS: High-frequency ultrasound measurement of skin and subcutaneous fat thickness is precise and reliable for in vivo assessment of body fat in newborn infants. Further validation of the technique relative to neonatal skin and nutritional state is, however, needed before the ultrasound technique can be used as routine in neonatalogical monitoring.

Key concepts: Calipers, Ultrasound, Subcutaneous fat, Medicine, Skinfold thickness, Skin thickness, Dermis, Skin fold

Related papers

Back to paper searchBrowse research topicsOriginal source
High‐frequency ultrasound measurement of dermis and subcutaneous fat in the newborn infant — Research Paper | ScholarLens