1993Journal of Cataract & Refractive SurgeryRequires access

Experimental evaluation of posterior capsule opacification and intraocular lens decentration: Comparison of intraocular lenses of 12.5 mm and 14.0 mm diameter

Shunsaku Ohmi, K Uenoyama

Open publisher page 18 citations

Abstract

Most posterior chamber intraocular lenses (IOLs) in common use today measure 13.5 mm to 14.0 mm in diameter. Some investigators recommend using smaller lenses (e.g., 12.0 mm to 12.5 mm). To investigate the effect of smaller lenses, experimental phacoemulsification procedures were performed in 16 eyes of white rabbits using two intraocular lens sizes: 14.0 mm and 12.5 mm. Each lens was evaluated for its effects on posterior capsule opacification and optic decentration, two of the most common complications of modern cataract surgery and intraocular lens implantation. The 12.5 mm lens showed a slightly smaller amount of decentration than the larger lens and a comparable amount of posterior capsule opacification.

About this research paper

What this paper is about

Most posterior chamber intraocular lenses (IOLs) in common use today measure 13.5 mm to 14.0 mm in diameter. Some investigators recommend using smaller lenses (e.g., 12.0 mm to 12.5 mm). To investigate the effect of smaller lenses, experimental phacoemulsification procedures were performed in 16 eyes of white rabbits using two intraocular lens sizes: 14.0 mm and 12.5 mm. Each lens was evaluated for its effects on posterior capsule opacification and optic decentration, two of the most common complications of modern cataract surgery and intraocular lens implantation. The 12.5 mm lens showed a slightly smaller amount of decentration than the larger lens and a comparable amount of posterior capsule opacification.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Most posterior chamber intraocular lenses (IOLs) in common use today measure 13.5 mm to 14.0 mm in diameter. Some investigators recommend using smaller lenses (e.g., 12.0 mm to 12.5 mm). To investigate the effect of smaller lenses, experimental phacoemulsification procedures were performed in 16 eyes of white rabbits using two intraocular lens sizes: 14.0 mm and 12.5 mm. Each lens was evaluated for its effects on posterior capsule opacification and optic decentration, two of the most common complications of modern cataract surgery and intraocular lens implantation. The 12.5 mm lens showed a slightly smaller amount of decentration than the larger lens and a comparable amount of posterior capsule opacification.

Key concepts: Intraocular lenses, Intraocular lens, Ophthalmology, Posterior capsule opacification, Lens capsule, Lens (geology), Medicine, Phacoemulsification

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental evaluation of posterior capsule opacification and intraocular lens decentration: Comparison of intraocular lenses of 12.5 mm and 14.0 mm diameter — Research Paper | ScholarLens