TESTING TENSIOMETERS BY A VACUUM METHOD

W. E. PUCKETT, Jacob H. Dane

Open publisher page 7 citations

Abstract

We developed a quick vacuum method to test for and locate leaks in tensiometers. The method consists of first applying vacuum to a dry tensiometer to test for possible leaks at that end of the tensiometer that is connected to a manometer or other pressure-measuring device. Secondly, the tensiometer is subjected to vacuum after the porous cup has been thoroughly wetted. The latter should indicate any leaks in the porous cup itself or between the cup and the tensiometer tube. The method takes approximately 10 minutes of testing per tensiometer.

About this research paper

What this paper is about

We developed a quick vacuum method to test for and locate leaks in tensiometers. The method consists of first applying vacuum to a dry tensiometer to test for possible leaks at that end of the tensiometer that is connected to a manometer or other pressure-measuring device. Secondly, the tensiometer is subjected to vacuum after the porous cup has been thoroughly wetted. The latter should indicate any leaks in the porous cup itself or between the cup and the tensiometer tube. The method takes approximately 10 minutes of testing per tensiometer.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We developed a quick vacuum method to test for and locate leaks in tensiometers. The method consists of first applying vacuum to a dry tensiometer to test for possible leaks at that end of the tensiometer that is connected to a manometer or other pressure-measuring device. Secondly, the tensiometer is subjected to vacuum after the porous cup has been thoroughly wetted. The latter should indicate any leaks in the porous cup itself or between the cup and the tensiometer tube. The method takes approximately 10 minutes of testing per tensiometer.

Key concepts: Tensiometer (surface tension), Pressure measurement, Tube (container), Geotechnical engineering, Materials science, Mechanical engineering, Engineering, Composite material