An Alternative Tensiometer Design for Deep Vadose Zone Monitoring
Maziar M. Kandelous, Barzin A. Moradi, J. W. Hopmans
Abstract
Open-access reader
Maziar M. Kandelous, Barzin A. Moradi, J. W. Hopmans
Abstract
Open-access reader
The conventional tensiometer is among the most accurate devices for soil water matric potential measurements, as well as for estimations of soil water flux from soil water potential gradients. Uncertainties associated with conventional tensiometers such as caused by ambient temperature effects and the draining of the tensiometer tube, as well as their limitation for deep soil monitoring, has prevented their widespread use for vadose zone monitoring, despite their superior accuracy in general. We introduce an alternative tensiometer design that offers the accuracy of the conventional tensiometer, while minimizing the aforementioned uncertainties and limitations. The proposed alternative tensiometer largely eliminates temperature-induced diurnal fluctuations and uncertainties associated with draining of the tensiometer tube and removes the limitation in installation depth. In addition, the manufacturing costs of this alternative tensiometer design are close to those of the conventional tensiometer, while it is especially suited for monitoring of soil water potential gradients as required for soil water flux measurements.
OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The conventional tensiometer is among the most accurate devices for soil water matric potential measurements, as well as for estimations of soil water flux from soil water potential gradients. Uncertainties associated with conventional tensiometers such as caused by ambient temperature effects and the draining of the tensiometer tube, as well as their limitation for deep soil monitoring, has prevented their widespread use for vadose zone monitoring, despite their superior accuracy in general. We introduce an alternative tensiometer design that offers the accuracy of the conventional tensiometer, while minimizing the aforementioned uncertainties and limitations. The proposed alternative tensiometer largely eliminates temperature-induced diurnal fluctuations and uncertainties associated with draining of the tensiometer tube and removes the limitation in installation depth. In addition, the manufacturing costs of this alternative tensiometer design are close to those of the conventional tensiometer, while it is especially suited for monitoring of soil water potential gradients as required for soil water flux measurements.
Key concepts: Tensiometer (surface tension), Vadose zone, Water potential, Environmental science, Soil water, Soil science, Hydrology (agriculture), Geotechnical engineering