2010•Physics in Medicine and BiologyRequires access

Gafchromic EBT film dosimetry in proton beams

Zhao Li, Indra J. Das

Open publisher page 145 citations

Abstract

The depth dose verification of active scanning proton beams is extremely time consuming with ion chamber measurements for beam data commissioning and patient specific measurements. With widespread use of Gafchromic EBT films, two-dimensional high-resolution dosimetry is explored in a uniform scanning proton beam. The EBT films were exposed parallel to the beam axis in a solid water phantom in order to obtain the depth-dose curve in a single measurement and compared with the gold standard measurement with a parallel plate ion chamber in water. Our results demonstrate that EBT films perform well in determining the proton beam range, with uncertainty of 0.5 mm. It is also found that EBT film response is a function of energy over the effective energy of 50-160 MeV proton beams with the variations less than 10%. However, an under-dosage of up to 20% was observed at the peak of the Bragg curve. An empirically derived correction factor is proposed to account for the EBT energy dependence. With corrections, EBT films can be a useful tool for the depth dose verification of active scanning proton beams, thus saving valuable proton beam time.

About this research paper

What this paper is about

The depth dose verification of active scanning proton beams is extremely time consuming with ion chamber measurements for beam data commissioning and patient specific measurements. With widespread use of Gafchromic EBT films, two-dimensional high-resolution dosimetry is explored in a uniform scanning proton beam. The EBT films were exposed parallel to the beam axis in a solid water phantom in order to obtain the depth-dose curve in a single measurement and compared with the gold standard measurement with a parallel plate ion chamber in water. Our results demonstrate that EBT films perform well in determining the proton beam range, with uncertainty of 0.5 mm. It is also found that EBT film response is a function of energy over the effective energy of 50-160 MeV proton beams with the variations less than 10%. However, an under-dosage of up to 20% was observed at the peak of the Bragg curve. An empirically derived correction factor is proposed to account for the EBT energy dependence. With corrections, EBT films can be a useful tool for the depth dose verification of active scanning proton beams, thus saving valuable proton beam time.

Why it matters

OpenAlex reports 145 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The depth dose verification of active scanning proton beams is extremely time consuming with ion chamber measurements for beam data commissioning and patient specific measurements. With widespread use of Gafchromic EBT films, two-dimensional high-resolution dosimetry is explored in a uniform scanning proton beam. The EBT films were exposed parallel to the beam axis in a solid water phantom in order to obtain the depth-dose curve in a single measurement and compared with the gold standard measurement with a parallel plate ion chamber in water. Our results demonstrate that EBT films perform well in determining the proton beam range, with uncertainty of 0.5 mm. It is also found that EBT film response is a function of energy over the effective energy of 50-160 MeV proton beams with the variations less than 10%. However, an under-dosage of up to 20% was observed at the peak of the Bragg curve. An empirically derived correction factor is proposed to account for the EBT energy dependence. With corrections, EBT films can be a useful tool for the depth dose verification of active scanning proton beams, thus saving valuable proton beam time.

Key concepts: Proton, Dosimetry, Bragg peak, Materials science, Beam (structure), Proton therapy, Imaging phantom, Range (aeronautics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Gafchromic EBT film dosimetry in proton beams — Research Paper | ScholarLens