Therapeutic Proton Beam Range Measurement with EBT3 Film and Comparison with Tool for Particle Simulation

Nuri Lee, Chankyu Kim, Mi Hee Song, Se Byeong Lee

Open full text 3 citations

Abstract

Purpose: The advantages of ocular proton therapy are that it spares the optic nerve and delivers the minimal dose to normal surrounding tissues.In this study, it developed a solid eye phantom that enabled us to perform quality assurance (QA) to verify the dose and beam range for passive single scattering proton therapy using a single phantom.For this purpose, a new solid eye phantom with a polymethyl-methacrylate (PMMA) wedge was developed using film dosimetry and an ionization chamber.Methods: The typical beam shape used for eye treatment is approximately 3 cm in diameter and the beam range is below 5 cm.Since proton therapy has a problem with beam range uncertainty due to differences in the stopping power of normal tissue, bone, air, etc, the beam range should be confirmed before treatment.A film can be placed on the slope of the phantom to evaluate the Spread-out Bragg Peak based on the water equivalent thickness value of PMMA on the film.In addition, an ionization chamber (Pin-point, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose.Results: The eye phantom was used for independent patient-specific QA.The differences in the output and beam range between the measurement and the planned treatment were less than 1.5% and 0.1 cm, respectively.Conclusions: An eye phantom was developed and the performance was successfully validated.The phantom can be employed to verify the output and beam range for ocular proton therapy.

Open-access reader

About this research paper

What this paper is about

Purpose: The advantages of ocular proton therapy are that it spares the optic nerve and delivers the minimal dose to normal surrounding tissues.In this study, it developed a solid eye phantom that enabled us to perform quality assurance (QA) to verify the dose and beam range for passive single scattering proton therapy using a single phantom.For this purpose, a new solid eye phantom with a polymethyl-methacrylate (PMMA) wedge was developed using film dosimetry and an ionization chamber.Methods: The typical beam shape used for eye treatment is approximately 3 cm in diameter and the beam range is below 5 cm.Since proton therapy has a problem with beam range uncertainty due to differences in the stopping power of normal tissue, bone, air, etc, the beam range should be confirmed before treatment.A film can be placed on the slope of the phantom to evaluate the Spread-out Bragg Peak based on the water equivalent thickness value of PMMA on the film.In addition, an ionization chamber (Pin-point, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose.Results: The eye phantom was used for independent patient-specific QA.The differences in the output and beam range between the measurement and the planned treatment were less than 1.5% and 0.1 cm, respectively.Conclusions: An eye phantom was developed and the performance was successfully validated.The phantom can be employed to verify the output and beam range for ocular proton therapy.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose: The advantages of ocular proton therapy are that it spares the optic nerve and delivers the minimal dose to normal surrounding tissues.In this study, it developed a solid eye phantom that enabled us to perform quality assurance (QA) to verify the dose and beam range for passive single scattering proton therapy using a single phantom.For this purpose, a new solid eye phantom with a polymethyl-methacrylate (PMMA) wedge was developed using film dosimetry and an ionization chamber.Methods: The typical beam shape used for eye treatment is approximately 3 cm in diameter and the beam range is below 5 cm.Since proton therapy has a problem with beam range uncertainty due to differences in the stopping power of normal tissue, bone, air, etc, the beam range should be confirmed before treatment.A film can be placed on the slope of the phantom to evaluate the Spread-out Bragg Peak based on the water equivalent thickness value of PMMA on the film.In addition, an ionization chamber (Pin-point, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose.Results: The eye phantom was used for independent patient-specific QA.The differences in the output and beam range between the measurement and the planned treatment were less than 1.5% and 0.1 cm, respectively.Conclusions: An eye phantom was developed and the performance was successfully validated.The phantom can be employed to verify the output and beam range for ocular proton therapy.

Key concepts: Imaging phantom, Ionization chamber, Proton therapy, Materials science, Particle therapy, Bragg peak, Beam (structure), Dosimetry

Related papers

Back to paper searchBrowse research topicsOriginal source
Therapeutic Proton Beam Range Measurement with EBT3 Film and Comparison with Tool for Particle Simulation — Research Paper | ScholarLens