Quantitative in Vitro Comparison of Fluorescein Delivery to the Eye via Impregnated Paper Strip and Volumetric Techniques

Ahmad M. Abdul‐Fattah, Hridaya N. Bhargava, Donald R. Korb, Thomas Glonek, Victor M. Finnemore, Jack V. Greiner

Open publisher page 23 citations

Abstract

PURPOSE: To compare the quantity of fluorescein delivered to the eye via fluorescein-impregnated paper strips of various sizes and surface areas and via various microliter volumes of fluorescein sodium using an in vitro assay. METHODS: A commercially available fluorescein-impregnated strip (75 mm2) and three modified strips of reduced fluorescein-impregnated surface areas (10, 7.5, and 5.0 mm2) were used. The amount of fluorescein delivered to the eye for each of the four strips was approximated by applying each strip to a Whatman No. 1 filter paper under conditions simulating application of the strip to the eye, extracting the fluorescein from the filter paper in an aqueous solution, and performing spectrophotometric analysis at 484 nm. Similarly, this filter paper analytical system was calibrated using 1, 2, and 3 microl volumes of 2% w/v fluorescein delivered to the filter paper. RESULTS: Using calibration curves, linearity was observed between absorbance and concentration of fluorescein sodium with an R2 value > or = 0.99. Using these calibration curves, the amount of fluorescein delivered to the eye for the four strips and the three fluorescein solution samples was determined. Fluorescein-impregnated strips with surface areas of 75, 10, and 5 mm2 delivered approximately the same quantity of fluorescein to the ocular surface as 3 microl, 1 microl, and 0.5 microl of fluorescein 2% solution, respectively. CONCLUSIONS: The surface area of the fluorescein-impregnated portion of the strip can be designed to control the amount of fluorescein delivered to the eye.

About this research paper

What this paper is about

PURPOSE: To compare the quantity of fluorescein delivered to the eye via fluorescein-impregnated paper strips of various sizes and surface areas and via various microliter volumes of fluorescein sodium using an in vitro assay. METHODS: A commercially available fluorescein-impregnated strip (75 mm2) and three modified strips of reduced fluorescein-impregnated surface areas (10, 7.5, and 5.0 mm2) were used. The amount of fluorescein delivered to the eye for each of the four strips was approximated by applying each strip to a Whatman No. 1 filter paper under conditions simulating application of the strip to the eye, extracting the fluorescein from the filter paper in an aqueous solution, and performing spectrophotometric analysis at 484 nm. Similarly, this filter paper analytical system was calibrated using 1, 2, and 3 microl volumes of 2% w/v fluorescein delivered to the filter paper. RESULTS: Using calibration curves, linearity was observed between absorbance and concentration of fluorescein sodium with an R2 value > or = 0.99. Using these calibration curves, the amount of fluorescein delivered to the eye for the four strips and the three fluorescein solution samples was determined. Fluorescein-impregnated strips with surface areas of 75, 10, and 5 mm2 delivered approximately the same quantity of fluorescein to the ocular surface as 3 microl, 1 microl, and 0.5 microl of fluorescein 2% solution, respectively. CONCLUSIONS: The surface area of the fluorescein-impregnated portion of the strip can be designed to control the amount of fluorescein delivered to the eye.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To compare the quantity of fluorescein delivered to the eye via fluorescein-impregnated paper strips of various sizes and surface areas and via various microliter volumes of fluorescein sodium using an in vitro assay. METHODS: A commercially available fluorescein-impregnated strip (75 mm2) and three modified strips of reduced fluorescein-impregnated surface areas (10, 7.5, and 5.0 mm2) were used. The amount of fluorescein delivered to the eye for each of the four strips was approximated by applying each strip to a Whatman No. 1 filter paper under conditions simulating application of the strip to the eye, extracting the fluorescein from the filter paper in an aqueous solution, and performing spectrophotometric analysis at 484 nm. Similarly, this filter paper analytical system was calibrated using 1, 2, and 3 microl volumes of 2% w/v fluorescein delivered to the filter paper. RESULTS: Using calibration curves, linearity was observed between absorbance and concentration of fluorescein sodium with an R2 value > or = 0.99. Using these calibration curves, the amount of fluorescein delivered to the eye for the four strips and the three fluorescein solution samples was determined. Fluorescein-impregnated strips with surface areas of 75, 10, and 5 mm2 delivered approximately the same quantity of fluorescein to the ocular surface as 3 microl, 1 microl, and 0.5 microl of fluorescein 2% solution, respectively. CONCLUSIONS: The surface area of the fluorescein-impregnated portion of the strip can be designed to control the amount of fluorescein delivered to the eye.

Key concepts: Fluorescein, Sodium fluorescein, STRIPS, Absorbance, Calibration, Biomedical engineering, Chromatography, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantitative in Vitro Comparison of Fluorescein Delivery to the Eye via Impregnated Paper Strip and Volumetric Techniques — Research Paper | ScholarLens